2017
DOI: 10.1515/zpch-2017-0003
|View full text |Cite
|
Sign up to set email alerts
|

Study on Host-Guest Inclusion Complexation of a Drug in Cucurbit [6]uril

Abstract: Assembly of pyridine-2-aldoxime drug with cucurbit [6]uril (CB[6]) has been investigated by1H-NMR and 2D-ROESY NMR, UV-Vis spectroscopy, FT-IR spectroscopy, surface tension and conductivity measurements in aqueous saline environment. The distinct cationic receptor feature and the cavity dimension of the CB[6] emphasize that the macro-cyclic host molecule remain as complex with the nerve stimulus drug molecule. The results obtained from surface tension and specific conductivity measurements suggest 1:1 inclusio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…This molality was then converted into molar conductivity using the formula = 1000 κ/ c , where c is the molar concentration of the tartrazine (dye) solutions in the ILs. The specific conductivity of the above-mentioned solutions is indicated by κ. …”
Section: Methodsmentioning
confidence: 99%
“…This molality was then converted into molar conductivity using the formula = 1000 κ/ c , where c is the molar concentration of the tartrazine (dye) solutions in the ILs. The specific conductivity of the above-mentioned solutions is indicated by κ. …”
Section: Methodsmentioning
confidence: 99%
“…Systronics-308 conductivity meter was used to measure the Specific conductivity of the solutions of working frequency 1 kHz with an accuracy of ±1%. The calibration of conductivity cell was determined and determination of cell constant of the cell that proposed by the technique as suggested by Lind et al [22]. For the determination of cell constant freshly prepared 0.01 M aqueous KCl solution was used and it was maintained within the range 0.09-1.00 cm −1 during the experiment of the solutions.…”
Section: Methodsmentioning
confidence: 99%
“…The measurement of conductivity of the solutions were carried out in a Systronics-308 conductivity meter (accuracy ±0.01%) using a dip-type immersion conductivity cell (CD-10) whose cell constant was (0.1 ± 0.001) cm−1 approximately. Measurements were completed in a water bath with an accuracy of ± 0.01 K at the desired temperature [16]. A Tensiometer (K9, KRUSS; Germany) was used to measure the surface tensions of the solutions at 298.15K using the platinum ring detachment technique.…”
Section: Methodsmentioning
confidence: 99%