2015
DOI: 10.1109/tgrs.2014.2372786
|View full text |Cite
|
Sign up to set email alerts
|

Study on Influences of Atmospheric Factors on Vertical $\mbox{CO}_{2} $ Profile Retrieving From Ground-Based DIAL at 1.6 μm

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 29 publications
(16 citation statements)
references
References 39 publications
0
16
0
Order By: Relevance
“…Relevant line parameters are according to HITRAN 2016 [66]. A further description of relevant parameters, such as molecular spectra, laser line shape, etc., and the equation of the Voigt profile can be found in references on laser spectroscopy [39,41,58,67]. It is worth noting that an optical filter with an extreme narrow bandwidth is required to minimize the solar background.…”
Section: Appendix B Description Of Calculation Methods Of the Random mentioning
confidence: 99%
See 1 more Smart Citation
“…Relevant line parameters are according to HITRAN 2016 [66]. A further description of relevant parameters, such as molecular spectra, laser line shape, etc., and the equation of the Voigt profile can be found in references on laser spectroscopy [39,41,58,67]. It is worth noting that an optical filter with an extreme narrow bandwidth is required to minimize the solar background.…”
Section: Appendix B Description Of Calculation Methods Of the Random mentioning
confidence: 99%
“…The absorption cross-section is calculated by using the Voigt profile which requires the Lorentzian half-width half-maximum (HWHM) as one of the input variables. The Lorentzian HWHM is a function of the pressure [58]. Consequently, the uncertainty of the pressure will propagate to the determination of the Lorentzian HWHM and will eventually propagate to the estimations of the number density for CO2.…”
Section: Estimation Of the Systematic Errormentioning
confidence: 99%
“…Further descriptions of relevant parameters, such as molecular spectra, laser line shape, etc., can be found in existing studies [24,29,30] or textbooks [31].…”
Section: Random Errorsmentioning
confidence: 99%
“…In selecting the operating wavelength, we had to consider many factors, such as low temperature sensitivity and low interference from other molecules. Previous studies showed that H 2 O is the most critical interference molecule in the absorption spectroscopy of CO 2 [31,32]. As shown in Figure 2, R10, R12, and R20 are inappropriate because they are considerably affected by interferences from H 2 O. R16 is the most appropriate because the intensity of this peak is the strongest, and the influence of H 2 O in this band is less than that in R14 and R18.…”
Section: Simulation Analysismentioning
confidence: 97%
“…Most spectroscopic parameters of CO 2 lines for the simulation analysis were obtained from Predoi-Cross et al [28] and HITRAN 2012 [29]. The spectroscopic parameters of the absorption lines of H 2 O were obtained from HITEMP 2010 [30,31]. According to the HITRAN 2012 molecular spectroscopic database, six absorption lines in the range of the 30012-00001 carbon-dioxide band were studied because their intensities were evidently higher than those of others.…”
Section: Simulation Analysismentioning
confidence: 99%