Study on Monitoring System for Partial Discharge of Electrical Equipment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…As shown in Figure 1, between the high-voltage cables, wires and metal shielding insulating material is separated form the distributed capacitance, the capacitance of only a few hundred skin method, to the high frequency signal as a good conductor [8,9]. Therefore, high frequency discharge signal transmission circuit formed by the distributed capacitor grounding wire, wire installed broadband current transducer (HFCT) could be detected in the discharge pulse signal on cable shielded joint joint and can determine magnitude of partial discharge.…”
Section: Signal Extraction Methodsmentioning
confidence: 99%
“…As shown in Figure 1, between the high-voltage cables, wires and metal shielding insulating material is separated form the distributed capacitance, the capacitance of only a few hundred skin method, to the high frequency signal as a good conductor [8,9]. Therefore, high frequency discharge signal transmission circuit formed by the distributed capacitor grounding wire, wire installed broadband current transducer (HFCT) could be detected in the discharge pulse signal on cable shielded joint joint and can determine magnitude of partial discharge.…”
Section: Signal Extraction Methodsmentioning
confidence: 99%
“…Breakdown voltage or a few researchers called as partial discharge is defined as an electrical discharge that does not completely bridge the insulation between two electrodes or conductors [9], [14]. This testing method is used to measure the maximum voltage that can be held by the insulator.…”
Section: Breakdown Voltage Measurementmentioning
confidence: 99%
“…This type of insulation damage and aging is characterized by the accumulation of conductor terminal charges, ionization from the impact of charged particles on air molecules, chemical formation, and damage from ionizing radiation to insulation materials [5][6][7]. Therefore, it is of great importance to conduct research and develop an early warning and analysis methods for detecting PD occurrences to ensure the safety and normal operation of power transmission equipment [8][9][10].…”
Section: Introductionmentioning
confidence: 99%