Study on Operation Parameter Characteristics of Induction Filter Distribution Transformer in Low-Voltage Distribution Network

Abstract: There is a need for induction filter technology in the field of low-voltage distribution networks. This paper proposes an induction filter distribution transformer with a unique Dd0yn11 threewinding configuration. This approach allows for the control of load side harmonics in low-voltage distribution networks. At present, the induction filter technology proposed in the known literature is mostly used in the high-voltage power system, but there is still no research on the application of induction filter technol… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…On the valve side, the triangular connection is adopted to shield the 3rd harmonic and suppress the influence of zero sequence current [21]. In the LV distribution network, in order to obtain two voltages on the load side, the transformer winding generally adopts Dy wiring, which is mainly because the star connected on the load side has stronger capacity than the unbalanced load connected in triangle, and the three-phase unbalanced load needs to be grounded, which can meet the needs of urban power distribution [22,23].…”
Section: Introductionmentioning
confidence: 99%
“…On the valve side, the triangular connection is adopted to shield the 3rd harmonic and suppress the influence of zero sequence current [21]. In the LV distribution network, in order to obtain two voltages on the load side, the transformer winding generally adopts Dy wiring, which is mainly because the star connected on the load side has stronger capacity than the unbalanced load connected in triangle, and the three-phase unbalanced load needs to be grounded, which can meet the needs of urban power distribution [22,23].…”
Section: Introductionmentioning
confidence: 99%
“…Overall, the inductive filter can inhibit harmonics and prevent them from flowing through the transformer's winding connected to distribution systems. It can thus reduce the harmonics' adverse impact on transformers [19].…”
Section: Introductionmentioning