2018
DOI: 10.3390/en11020416
|View full text |Cite
|
Sign up to set email alerts
|

Study on the Hazard Limitation of Hybrid Circuit Breaker Actuator Operation

Abstract: Abstract:The paper deals with a key issue, how to limit the hazard and assure reliability, safety and repeatability of operation of selected critical devices protecting electrical power systems. The main research is focused on the incorrect operation of hybrid switches caused by random disturbances of the thyristor gate signals in the electrodynamic drive coil power supply circuit. Firstly, a pilot experiment on the operation of hybrid circuit breaker actuators under random disturbance conditions was carried o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…The above advantages of the IDD resulted in its taking over from other types of drives (e.g., spring ones) in many circuit breakers, especially in the so-called hybrid circuit breakers (Figure 1b) of both DC [20][21][22][23][24][25][26] and AC used in synchronous switchingoff [27][28][29][30][31][32][33]. The interest of the authors in the study of this type of drive is mainly related to their application in the class of circuit breakers considered [30,[32][33][34][35][36][37][38][39][40][41]. The authors' noted works can be divided into those focusing on the study of electromagnetic [35,40], mechanical [34,38], and thermal [41] phenomena of the drive.…”
Section: Inductive Dynamic Drive (Idd)mentioning
confidence: 99%
See 3 more Smart Citations
“…The above advantages of the IDD resulted in its taking over from other types of drives (e.g., spring ones) in many circuit breakers, especially in the so-called hybrid circuit breakers (Figure 1b) of both DC [20][21][22][23][24][25][26] and AC used in synchronous switchingoff [27][28][29][30][31][32][33]. The interest of the authors in the study of this type of drive is mainly related to their application in the class of circuit breakers considered [30,[32][33][34][35][36][37][38][39][40][41]. The authors' noted works can be divided into those focusing on the study of electromagnetic [35,40], mechanical [34,38], and thermal [41] phenomena of the drive.…”
Section: Inductive Dynamic Drive (Idd)mentioning
confidence: 99%
“…References [36][37][38] present the development of measurement systems that allow the experimental determination of the basic drive quantities. Finally, articles [30,39] describe the results of tests on hybrid switches in which the basic element is the actuator. More detailed descriptions can be found later in the article, where most of the papers [30][31][32][33][34][35][36][37][38][39][40][41] are further referenced.…”
Section: Inductive Dynamic Drive (Idd)mentioning
confidence: 99%
See 2 more Smart Citations
“…To date, the commonly used SF 6 circuit breakers in 330 kV and 500 kV AC power systems have a long remove fault time of approximately 50 ms [4]. During this period, the fault current reaches its peak several times [5]. According to the dielectric strength, SF 6 behaves better than VCBs; hence, VCBs have higher dielectric strength restoration after the current is turned to zero, in comparison with other types of circuit breakers.…”
Section: Introductionmentioning
confidence: 99%