2013
DOI: 10.1103/physrevlett.110.160802
|View full text |Cite
|
Sign up to set email alerts
|

Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells

Abstract: Scalar atomic magnetometers have many attractive features but their sensitivity has been relatively poor. We describe a Rb scalar gradiometer using two multi-pass optical cells. We use a pump-probe measurement scheme to suppress spin-exchange relaxation and two probe pulses to find the spin precession zero crossing times with a resolution of 1 psec. We realize magnetic field sensitivity of 0.54 fT/Hz 1/2 , which improves by an order of magnitude the best scalar magnetometer sensitivity and surpasses the quantu… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

3
185
0
2

Year Published

2014
2014
2021
2021

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 302 publications
(212 citation statements)
references
References 30 publications
3
185
0
2
Order By: Relevance
“…In the last years research on optical magnetometers lead to enormous improvements, reaching sensitivities similar to SQUIDs [10,11]. The most sensitive optical magnetometers are even able to measure the weak signals of the human brain [12] and heart signals of an unborn child [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…In the last years research on optical magnetometers lead to enormous improvements, reaching sensitivities similar to SQUIDs [10,11]. The most sensitive optical magnetometers are even able to measure the weak signals of the human brain [12] and heart signals of an unborn child [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Atoms can be configured as magnetometers that achieve sensitivity slightly better than other available technologies [1]. These sensors have been used to achieve magnetic noise free regions [2][3][4][5], to study biomagnetism [6,7], to generate squeezing in spin systems [8][9][10] or to look for physics beyond the Standard Model [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Alternatively, we have operated similar magnetometers in an alloptical mode as well as the Mz mode, with similar sensitivities of 5 pT/Hz 1/2 . For microfabricated scalar magnetometers, sensitivity could be increased by implementing a balanced polarimeter [12,13], a multipass cell [14], or through light narrowing [15].…”
Section: Introductionmentioning