2023
DOI: 10.1039/d2nj04905h
|View full text |Cite
|
Sign up to set email alerts
|

Substitution preference of chromium ions in the clinker phase of ordinary Portland cement

Abstract: Using industrial solid waste to produce cement clinker not only effectively reduces the consumption of natural resources, but also reduces waste pollution. In this paper, the solidification tendency of Cr...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 50 publications
0
2
0
Order By: Relevance
“…Using the CV measurement for different scan rates, a calibration plot of anodic peak potential versus ln ν is plotted from which the slope is determined. In the irreversible voltammogram of CeO 2 @S-SC UA sensor, transfer coefficient (α) was found to be 0.45 and upon calculation the electron number (n) was determined to be 1.76 45 Hence, the two-electron/two-proton coupled transport mechanism (2e − +2H + ) can be verified via Laviron equation. Ag doped Fe 2 O 3 coupled with polyaniline (PANI) modified GCE was scanned at various scan rates (50-400 mV s −1 ) in PBS (pH = 7) containing 10 μM of UA.…”
Section: Pa Pcmentioning
confidence: 88%
See 1 more Smart Citation
“…Using the CV measurement for different scan rates, a calibration plot of anodic peak potential versus ln ν is plotted from which the slope is determined. In the irreversible voltammogram of CeO 2 @S-SC UA sensor, transfer coefficient (α) was found to be 0.45 and upon calculation the electron number (n) was determined to be 1.76 45 Hence, the two-electron/two-proton coupled transport mechanism (2e − +2H + ) can be verified via Laviron equation. Ag doped Fe 2 O 3 coupled with polyaniline (PANI) modified GCE was scanned at various scan rates (50-400 mV s −1 ) in PBS (pH = 7) containing 10 μM of UA.…”
Section: Pa Pcmentioning
confidence: 88%
“…When GCE is modified with CeO 2 @S-SC, the A eff significantly increased from 0.07 cm 2 to 3.46 cm 2 which was calculated from Randles-Sevick equation. 45 The number of electrons taking part in electrochemical oxidation depends on the type of analyte under investigation. UA undergoes a 2e − transfer process and Laviron equation is used to validate the number of electrons transferred during the reaction.…”
Section: Pa Pcmentioning
confidence: 99%