Successful Retrieval of a Stuck Guidewire by Guiding Catheter Lock Technique in Renal Artery Stenting

Abstract: Introduction The guiding catheter lock technique is a therapeutic technique to increase backup force of the guiding catheter in coronary artery interventions. Surgical technique A 71 year old man presented with rapidly declining kidney function resulting from bilateral renal artery stenosis. During the renal artery stenting procedure, the 0.014" guidewire became trapped at the stent's distal edge. Although attempts were made to advance a microcatheter and balloon cathet… Show more