1994
DOI: 10.1016/0142-0615(94)90047-7
|View full text |Cite
|
Sign up to set email alerts
|

Supply of an entirely passive AC system through an HVDC link

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2004
2004
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…There has been in depth growth and fast development within the exploitation of wind energy in recent years. The individual units is of huge capability up to 2 MW, feeding into distribution network, particularly with customers connected in close proximity [3]. Today quite 28000 wind generating turbines are unit with success operational everywhere in the world.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…There has been in depth growth and fast development within the exploitation of wind energy in recent years. The individual units is of huge capability up to 2 MW, feeding into distribution network, particularly with customers connected in close proximity [3]. Today quite 28000 wind generating turbines are unit with success operational everywhere in the world.…”
Section: Introductionmentioning
confidence: 99%
“…The disadvantage of using shunt condenser is that the reactive power supplied is proportional to the square of the voltage. Consequently, the reactive power supplied from the capacitors decreases rapidly when the voltage decreases [3] .To overcomes the above disadvantages; STATCOM is best suited for reactive power compensation and harmonic reduction. It is based on a controllable voltage source converter (VSC).…”
Section: Introductionmentioning
confidence: 99%
“…For point to point HVDC schemes, unlike back-to-back schemes, the communication delay and/or the requirements for the system to operate without communications largely limit the possibility of reactive power control. Most of the literatures are then focused on reactive power compensation rather than reducing reactive consumption level of converter [4][5][6][7][8][9][10][11][12]. In those methods, external reactive compensation devices are installed at the inverter AC side.…”
Section: Introductionmentioning
confidence: 99%
“…Aside from AC voltage support, these methods provide the reactive power of the HVDC converters. These methods can be referred to in the literature [1][2][3][4][5][6]. The traditional devices to meet the requirements of HVDC converters for connecting to passive networks used to be synchronous condensers [1].…”
Section: Introductionmentioning
confidence: 99%
“…In [4], a static VAR compensator (STATCOM) was used along with a HVDC converter to supply an entirely passive AC system. In [5], the simultaneous application of a STATCOM and capacitor-commutated converter (CCC)-HVDC was proposed to supply a passive AC network.…”
Section: Introductionmentioning
confidence: 99%