2022
DOI: 10.1109/tim.2022.3178738
|View full text |Cite
|
Sign up to set email alerts
|

Suppression of Nonuniform Magnetic Fields in Magnetic Shielding System for SERF Co-Magnetometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…x along the x-axis through the optical rotation angle, which is detected by the balanced polarimeter [41]. Hence, the high sensitivity for rotation sensing can be realized by this SERF co-magnetometer.…”
Section: Methodsmentioning
confidence: 98%
See 1 more Smart Citation
“…x along the x-axis through the optical rotation angle, which is detected by the balanced polarimeter [41]. Hence, the high sensitivity for rotation sensing can be realized by this SERF co-magnetometer.…”
Section: Methodsmentioning
confidence: 98%
“…Yet, the strong transmission attenuation near the resonance still cannot be overcame and the stability of incident laser power is a challenge to be guaranteed [39]. Nevertheless, studies on the transverse pumping effect of the optical rotation detection system in recent years have revealed that the polarization rate error is a non-negligible term, such that the stability of transmission will also be affected by polarization fluctuation even with a linear polarized laser [40,41]. Therefore, there is an urgent need to develop a method for optics-based in situ co-magnetometer cell temperature (i.e., atomic density) measurement, which is not influenced by fluctuations in laser intensity.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, some researchers introduced transfer learning into different fields of study (Xu et al 2015;He et al 2022;Kuang et al 2022). In real application, researchers developed more deep neural network architecture for multiple scenarios (Zeng et al 2021;Fu et al 2022;Lin et al 2022;Peng et al 2022).…”
Section: Introductionmentioning
confidence: 99%
“…Electron precession magnetometers do not require low-temperature cooling and have developed rapidly in recent years. In particular, the sensitivity of SERF all-optical electron precession magnetometers can reach the fT or even aT level in near-zero magnetic fields [12][13][14][15]. There is significant application potential in magnetocardiography and magnetoencephalography measurements.…”
Section: Introductionmentioning
confidence: 99%