1996
DOI: 10.1109/61.489346
|View full text |Cite
|
Sign up to set email alerts
|

Suppression of VFT in 1100 kV GIS by adopting resistor-fitted disconnector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
2
2

Relationship

0
10

Authors

Journals

citations
Cited by 54 publications
(21 citation statements)
references
References 4 publications
0
20
0
1
Order By: Relevance
“…The most up-to-date overview of main methods for VFTO attenuation in GIS is given in papers [10], [11]. They include: disconnector equipped with damping resistor [12], disconnector with reduced voltage due to the trapped charge reduction during the disconnector opening operation (the so called Trapped Charge Voltage, TCV) [3,13], application of high frequency resonators [14], and application of magnetic material of different types [15], [16], [17], [18], [19], [21].…”
Section: B Overview Of Main Vfto Attenuation Methodsmentioning
confidence: 99%
“…The most up-to-date overview of main methods for VFTO attenuation in GIS is given in papers [10], [11]. They include: disconnector equipped with damping resistor [12], disconnector with reduced voltage due to the trapped charge reduction during the disconnector opening operation (the so called Trapped Charge Voltage, TCV) [3,13], application of high frequency resonators [14], and application of magnetic material of different types [15], [16], [17], [18], [19], [21].…”
Section: B Overview Of Main Vfto Attenuation Methodsmentioning
confidence: 99%
“…GIS LIWV 2400kV, can be considered a safety margin of 15% VFTO, not more than 2087kV. For GIS devices, IEC IEC60071-2:1996 [5][6][7][8] believes that the insulation insulation with the standard safety margin should be larger, 20%. Considering the VFTO wave front time is shorter than the lightning impulse wave time, the voltage of GIS insulation is slightly increased.…”
Section: The Damage Of Vfto For the Sysytemmentioning
confidence: 99%
“…When closing, auxiliary contact K1 first closed, access 100 Ω single-stage closing resistors, over a period of time (called the closing resistor connecting time), the main contact K closed. By doing these, it can achieve purpose of limit closing overvoltage [15,16]. Circuit breaker additional multistage closing resistor model shown in Figure 6, the principle is similar to circuit breaker additional single-stage closing resistor.…”
Section: (2) Linear Central Component Modelmentioning
confidence: 99%