2015
DOI: 10.1134/s2070205115010153
|View full text |Cite
|
Sign up to set email alerts
|

Supramolecular complexes: Determination of stability constants on the basis of various experimental methods

Abstract: Stability constants and formation enthalpies of supramolecular complexes of crown ethers and their cyclic and acyclic analogues are determined on the basis of experimental data obtained by different physicochemical methods in the terms of a general approach developed and implemented in the ChemEqui software package. The established regularities of variation of stability of complexes are discussed as dependent on the ligand structure, nature of the cation, solvent, and anion. The applicability of the suggested … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(9 citation statements)
references
References 181 publications
(185 reference statements)
0
9
0
Order By: Relevance
“…Fitting of 1 H NMR spectral changes can be achieved by local and global optimisation methods and there are a range of software programs available for this purpose 16 – 21 . This research used the commercially available HypNMR as it is suitable for fast exchange and is not limited by number of binding constants or nuclei 22 . As shown, (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Fitting of 1 H NMR spectral changes can be achieved by local and global optimisation methods and there are a range of software programs available for this purpose 16 – 21 . This research used the commercially available HypNMR as it is suitable for fast exchange and is not limited by number of binding constants or nuclei 22 . As shown, (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…For our analysis, we have used log K >5.5 as the threshold for strong metal binders. Log K ≈5.5 is real limit for accurate estimation of log K values by different methods: calorimetry, UV, Vis, IR and NMR spectroscopy, conductometry without applying special techniques including competitive complexation etc . In solution for this threshold, approximately 95 mol.…”
Section: Methodsmentioning
confidence: 99%
“…The initial analytical concentrations were 0.35-0.92 mM (8) and 0.27-0.48 mM (9). The protonation constants were estimated from four titrations using the CHEMEQUI program [36] freely available on the server [37]. CHEMEQUI evaluates equilibrium constants using four different algorithms: EQ, SIMPLEX, MONTE-CARLO, and the genetic algorithm SDE [38].…”
Section: Stability Constant Measurements and Calculationsmentioning
confidence: 99%