2013
DOI: 10.1016/j.bios.2012.08.036
|View full text |Cite
|
Sign up to set email alerts
|

Surface engineering for enhancement of sensitivity in an underlap-FET biosensor by control of wettability

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 48 publications
(11 citation statements)
references
References 11 publications
0
11
0
Order By: Relevance
“…Instead, it is the overall concavity of the structure, and the binding of biomolecules in concave areas, which results in higher sensitivity. This finding has important implications for the future of biosensors: efforts are underway to increase the limit of detection of biosensors by ensuring that biomolecules bind only to the NW directly (16,21). However, the conventional wisdom-that nanoscale structures are more sensitive-fails in this regime.…”
Section: Discussionmentioning
confidence: 99%
“…Instead, it is the overall concavity of the structure, and the binding of biomolecules in concave areas, which results in higher sensitivity. This finding has important implications for the future of biosensors: efforts are underway to increase the limit of detection of biosensors by ensuring that biomolecules bind only to the NW directly (16,21). However, the conventional wisdom-that nanoscale structures are more sensitive-fails in this regime.…”
Section: Discussionmentioning
confidence: 99%
“… Application Target RE Linker Surface Sensor Readout LOD Sample Ref. IV diagnosis GST-tagged-HA CMP-NANA/Biotin-tagged GST antibody APTES GA Gold-labeled streptavidin SiO 2 /SiNW CMOS-compatible FET Off-chip 1 fM Buffer solution (PBS) [ 60 ] AIV diagnosis AIa antibody SBP SiO 2 /CYTOPTM (hydrophobic) and Si 3 N 4 (hydrophilic) FET Off-chip 1.9 fM 0.19 pM Buffer solution (PBS) [ 61 ] AIV detection AIV mAbH5 MPTMS DTT biotin-HPDP SiNW SiNW-FET Off-chip 10 -17 M Buffer solution (PBS) [ 58 ] Detection of DNA Hybridization oligonucleotide sequences derived from the H5N1AIV 18-mer ssDNA Thiol chain mercaptohexanol Al/Au FET On-chip 100 pM Buffer solution (PBS) [ 59 ] APTES: (3-Aminopropyl) triethoxysilane, GST: glutathione S-transferase, CMP-NANA: Cytidine-50-monophosphate-N-acetylneuraminic acid, AIa: avian influenza antigen, SBP: silica binding protein, MPTMS: 3-mercaptopropyltrimethoxysilane, Biotin-HPDP: N-(6-(biotinamido)hexyl)-3’-(2’-pyridyldithio)-propionamide, DTT: dithiothreitol
Fig. 3 (a) A conceptual view of the proposed device.
…”
Section: Selective Adhesion On Fet For Biosensing Applicationsmentioning
confidence: 99%
“…The risk groups have been defined by American Heart Association and U.S. Disease Control and Prevention and separated to three levels that are low risk: less than 1 μg/ml, average risk: 1-3 μg/ml, and high risk: above 3 μg/ml. Recently, several miniaturized devices for CRP detection were reported, e.g., a piezoresistive micro-cantilever beam (Wee et al 2005), an antibody-coated magnetic particle immunoassay (Tsai et al 2007), a quartz crystal microbalance (QCM) immunosensor (Kurosawa et al 2004), a surface plasmon resonance (SPR) immunosensor (Hu et al 2006;Meyer et al 2006), a CMOS image sensor (Devadhasan et al 2012), an enzyme-linked immunosorbent assay (Pultar et al 2009;Wu et al 2002), and an electric current using a field-effect transistor (Kim et al 2013). Such applications give CRP detection time typically in the range of 10-40 min.…”
Section: Introductionmentioning
confidence: 99%