The cell incubation depends on the cultured surface, but various machining methods produce different surface topographies, but it has not been clear how it is related to the topographic feature until now. Hence, the machined Ti-6Al-4V surface is characterized for preosteoblasts incubation via different mechanical fabrication. The relationship between surface topography created by various machining methods and cell incubation behaviour was explored. The objective is to control the surface preosteoblasts growth in machining of biological titanium alloy. According to the cell growth kinetic, the cell incubation behaviour was first proposed and modelled in relation to microstructural dimension and culture duration. Then, the topological cultured microstructure surface was fabricated via mechanical fabrication. Finally, the cell initial adhesion and incubation behaviour on microstructured surface was investigated. It is shown that the surface undulation on machined microstructure is conducive to controlling the direction and distribution of cell incubation from cell growth kinetic model. The cell culture can be controlled on the peak with a small undulation, while it is concentred on the sidewall with a high aspect ratio. Increasing the aspect ratio extends cell growth, while low aspect ratio promotes initial cell adhesion and growth rate. Within the optimal cultured duration, the microstructured surface is more favourable for cell survival, and the cell growth keep positive beyond critical aspect ratio. As a result, the cell adhesion ability is topologically controlled to 5.4 times higher and the growth rate can be improved by 101.7% on milled microgrooved surface. It may be applied to the rapid production of biomedical Ti-6Al-4V implant.