2002
DOI: 10.1016/s0584-8547(01)00387-1
|View full text |Cite
|
Sign up to set email alerts
|

Surface interaction and chemical imaging in plasma spectrometry induced with a line-focused laser beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2002
2002
2016
2016

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 34 publications
(18 citation statements)
references
References 14 publications
0
18
0
Order By: Relevance
“…Primary focusing was accomplished by an antireflection (AR)-coated f ϭ 40 mm cylindrical lens that focused the ablation pulses to a line approximately 100 m in width. The line-focused laser beam sampled a much larger target area per pulse and provided a significant improvement in spectrum reproducibility over a 5ϫ microscope objective and conventional spherical lens [14]. The second cylindrical lens (AR coated, f ϭ 75.6 mm) was placed in front of the focusing lens with its axis rotated perpendicular to the focusing lens's axis.…”
Section: B Libsmentioning
confidence: 99%
“…Primary focusing was accomplished by an antireflection (AR)-coated f ϭ 40 mm cylindrical lens that focused the ablation pulses to a line approximately 100 m in width. The line-focused laser beam sampled a much larger target area per pulse and provided a significant improvement in spectrum reproducibility over a 5ϫ microscope objective and conventional spherical lens [14]. The second cylindrical lens (AR coated, f ϭ 75.6 mm) was placed in front of the focusing lens with its axis rotated perpendicular to the focusing lens's axis.…”
Section: B Libsmentioning
confidence: 99%
“…A sample size of 60 × 60 mm 2 with a step size of 50 µm was used, and the resulting quantified elemental maps correlated well with the data from conventional methods. Mateo [20] performed an automated line imaging arrangement for 2D and 3D generation of chemical maps of inclusions in stainless steel using LIBS. In comparison with the point-to-point LIBS mapping method, a 51-fold reduction in the number of pulses and analysis time was achieved when the microline imaging approach was employed.…”
Section: Introductionmentioning
confidence: 99%
“…In previous studies the microline approach has been applied successfully to the fast generation of surface chemical maps of the sample. 26,27 In the present work, this method has been tested for the first time to obtain additional depth information from the analysis and to generate multidimensional data sets incorporating LIP signal intensity versus wavelength and versus x-, y-and z-positions on the sample. To demonstrate the capability of the technique, edge connectors of a printed circuit board have been analysed.…”
Section: Introductionmentioning
confidence: 99%