Proceedings of the International Conference LACONA XI 2017
DOI: 10.12775/3875-4.09
|View full text |Cite
|
Sign up to set email alerts
|

Surface micro-profilometry for the assessment of the effects of traditional and innovative cleaning treatments of silver

Abstract: In the complex procedure for the conservation of a work of art, the effective monitoring of the surface treatment is an important step in order to establish a conservation protocol. The evaluation of the effects of the cleaning requires the inspection of the outermost layer with complementary diagnostic techniques to obtain information on both materials and surface morphology. In this interdisciplinary work, a custom optical micro-profilometry device based on laser conoscopic holography was used for testing th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…Conoscopic holography has been successfully applied to measure metal surfaces and evaluate the results of different cleaning methodologies. The signal-to-noise (SNR) ratio, provided by the instrument driver as a percentage value, was used to evaluate the quality of the output of the probe [23,24]. The authors [23] developed a routine to optimize the performance of the conoscopic holography probe for the multi-material characterization, demonstrated on a Russian icon.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Conoscopic holography has been successfully applied to measure metal surfaces and evaluate the results of different cleaning methodologies. The signal-to-noise (SNR) ratio, provided by the instrument driver as a percentage value, was used to evaluate the quality of the output of the probe [23,24]. The authors [23] developed a routine to optimize the performance of the conoscopic holography probe for the multi-material characterization, demonstrated on a Russian icon.…”
Section: Introductionmentioning
confidence: 99%
“…The signal-to-noise (SNR) ratio, provided by the instrument driver as a percentage value, was used to evaluate the quality of the output of the probe [23,24]. The authors [23] developed a routine to optimize the performance of the conoscopic holography probe for the multi-material characterization, demonstrated on a Russian icon. By using the SNR value as threshold, a stack of acquisitions with different laser settings is combined into a single optimized surface map.…”
Section: Introductionmentioning
confidence: 99%