2017
DOI: 10.1149/2.1461714jes
|View full text |Cite
|
Sign up to set email alerts
|

Surface PEDOT:Nafion Coatings for Enhanced Dopamine, Serotonin and Adenosine Sensing

Abstract: Electro-polymerization of Nafion perfluorinated resin and 3,4-ethylenedioxythiophene (EDOT) with two different surfactants yielded nanoscale improved surface coatings on carbon fiber microelectrodes. Increased sensitivity and good selectivity for sensing subsecond release of dopamine, serotonin and adenosine in the presence of large concentrations of ascorbic acid and DOPAC was demonstrated. Two different surfactants were used during electro-polymerization: sodium dodecyl sulfate or sodium dodecyl benzene sulf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
53
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(53 citation statements)
references
References 33 publications
0
53
0
Order By: Relevance
“…Demuru et al (2017) developed the surface of CFMEs by using electro-polymerization of Nafion perfluorinated resin and 3,4-ethylenedioxythiophene (EDOT) with two surfactants such as sodium dodecyl sulfate (SDS) or sodium dodecyl benzene sulfonate (SDBS) to synthesize coatings [114]. The surfactants used increased the solution conductivity and decreased the surface tension at the electrolyte electrode interface.…”
Section: Carbon-based Ec Sensormentioning
confidence: 99%
“…Demuru et al (2017) developed the surface of CFMEs by using electro-polymerization of Nafion perfluorinated resin and 3,4-ethylenedioxythiophene (EDOT) with two surfactants such as sodium dodecyl sulfate (SDS) or sodium dodecyl benzene sulfonate (SDBS) to synthesize coatings [114]. The surfactants used increased the solution conductivity and decreased the surface tension at the electrolyte electrode interface.…”
Section: Carbon-based Ec Sensormentioning
confidence: 99%
“…There are a limited number of reports in the literature of PEDOT:Nafion composites to date . Wang and Olbricht reported a procedure to electrodeposit PEDOT:Nafion on Pt electrodes starting from a commercially available Nafion solution, providing both electrochemical and surface morphology characterization .…”
Section: Introductionmentioning
confidence: 99%
“…These examples show that PEDOT:Nafion is an attractive material for biomedical device applications. However, none of the previous PEDOT:Nafion composites were designed to record or stimulate neural activity in vivo …”
Section: Introductionmentioning
confidence: 99%
“…The positively charged cysteamine self-assembled monolayer (SAM) discriminated DA from the negatively charged interference molecules (e.g., AA) on the aptamer, which provided the selectivity to the fabricated sensors. In the DA detection, the potential interference of AA and UA may be avoided by the careful design of the electrode and the selection of materials [59]. However, interference from structurally related neurochemicals (e.g., DA and EP) is challenging to avoid.…”
Section: In Vitro Detection Of Typical Neurotransmittersmentioning
confidence: 99%