Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Background Colostomy formation as part of the Hartmann’s procedure is often performed during emergency surgery as a damage limitation measure where attempts at bowel anastomosis and continuity are contraindicated. Hartmann’s reversal (HR) remains challenging and can be attempted through open surgery and various minimally invasive techniques (laparoscopic and robotic platforms). We aimed to analyse outcomes of conventional multi-port laparoscopy (CL) versus single-incision approach (SILS) in patients undergoing HR. Methods A comprehensive online search of various databases was conducted in accordance with PRISMA guidelines including Medline, PubMed, Embase, and Cochrane. Comparative studies of patients undergoing CL and SILS for HR were included. Analysed primary outcomes were total operative time and mortality rate. Secondary outcomes included post-operative complications, length of hospital stay, risk of visceral injury intra-operatively, and re-operation rate. Combined overall effect sizes were calculated using the random-effects model, and the Newcastle–Ottawa Scale (NOS) was used to assess bias. Results Two observational studies matching our inclusion criteria with a total of 160 patients (SILS 100 vs. CL 60) were included. Statistical difference was observed for one outcome measure: operative duration (MD − 44.79 CI − 65.54– − 24.04, P < 0.0001). No significant difference was seen in mortality rate (OR 1.66 CI 0.17–16.39, P = 0.66), overall post-operative complications (OR 0.60 CI 0.28–1.32, P = 0.20), length of stay (MD − 0.22 CI − 4.25–3.82, P = 0.92), Clavien-Dindo III + complications (OR 0.61 CI 0.15–2.53, P = 0.50), risk of visceral injury (OR 1.59 CI 0.30–8.31, P = 0.58), and re-operation rates (OR 0.73 CI 0.08–6.76, P = 0.78). Conclusion Accounting for study limitations, the SILS procedure seems to be quicker with non-inferior outcomes compared with the conventional multi-port approach. This may lead to better patient satisfaction and cosmesis and potentially reduce the risk of future incisional hernia occurrence. However, well-designed, randomised studies are needed to draw more robust conclusions and recommendations.
Background Colostomy formation as part of the Hartmann’s procedure is often performed during emergency surgery as a damage limitation measure where attempts at bowel anastomosis and continuity are contraindicated. Hartmann’s reversal (HR) remains challenging and can be attempted through open surgery and various minimally invasive techniques (laparoscopic and robotic platforms). We aimed to analyse outcomes of conventional multi-port laparoscopy (CL) versus single-incision approach (SILS) in patients undergoing HR. Methods A comprehensive online search of various databases was conducted in accordance with PRISMA guidelines including Medline, PubMed, Embase, and Cochrane. Comparative studies of patients undergoing CL and SILS for HR were included. Analysed primary outcomes were total operative time and mortality rate. Secondary outcomes included post-operative complications, length of hospital stay, risk of visceral injury intra-operatively, and re-operation rate. Combined overall effect sizes were calculated using the random-effects model, and the Newcastle–Ottawa Scale (NOS) was used to assess bias. Results Two observational studies matching our inclusion criteria with a total of 160 patients (SILS 100 vs. CL 60) were included. Statistical difference was observed for one outcome measure: operative duration (MD − 44.79 CI − 65.54– − 24.04, P < 0.0001). No significant difference was seen in mortality rate (OR 1.66 CI 0.17–16.39, P = 0.66), overall post-operative complications (OR 0.60 CI 0.28–1.32, P = 0.20), length of stay (MD − 0.22 CI − 4.25–3.82, P = 0.92), Clavien-Dindo III + complications (OR 0.61 CI 0.15–2.53, P = 0.50), risk of visceral injury (OR 1.59 CI 0.30–8.31, P = 0.58), and re-operation rates (OR 0.73 CI 0.08–6.76, P = 0.78). Conclusion Accounting for study limitations, the SILS procedure seems to be quicker with non-inferior outcomes compared with the conventional multi-port approach. This may lead to better patient satisfaction and cosmesis and potentially reduce the risk of future incisional hernia occurrence. However, well-designed, randomised studies are needed to draw more robust conclusions and recommendations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.