Abstract: An LC-MS/MS method for the trace-level determination of 3-alkyl-2-methoxypyrazines in Sauvignon blanc wines is described. 3-Isobutyl-2-methoxypyrazine (IBMP), 3-isopropyl-2-methoxypyrazine (IPMP) and 3-sec-butyl-2-methoxypyrazine (SBMP) were analyzed by reversed phase liquid chromatography coupled to atmospheric pressure chemical ionization, as electrospray ionization was found to suffer from matrix quenching effects. A sample preparation method involving distillation of wine followed by solvent extraction and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
18
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 41 publications
(21 citation statements)
references
References 14 publications
3
18
0
Order By: Relevance
“…Chromatographic analysis was performed as reported previously (Alberts et al, 2009), using a Waters Alliance 2695 liquid chromatograph (Waters Corporation, Milford, U.S.A.) coupled to a Micromass Quattro Premier XE tandem quadrupole mass spectrometric detector (Micromass Limited, Manchester, U.K.). Chromatographic separation was in reversed phase mode, employing a methanol and water gradient and a phenyl hexyl column (Phenomenex Luna, Torrance, U.S.A.) with dimensions 250 x 4.6 mm (3 µm particle size), thermostatted at 40°C.…”
Section: Chromatographic Details Lc-ms/ms Methods For the Determinatimentioning
confidence: 99%
See 4 more Smart Citations
“…Chromatographic analysis was performed as reported previously (Alberts et al, 2009), using a Waters Alliance 2695 liquid chromatograph (Waters Corporation, Milford, U.S.A.) coupled to a Micromass Quattro Premier XE tandem quadrupole mass spectrometric detector (Micromass Limited, Manchester, U.K.). Chromatographic separation was in reversed phase mode, employing a methanol and water gradient and a phenyl hexyl column (Phenomenex Luna, Torrance, U.S.A.) with dimensions 250 x 4.6 mm (3 µm particle size), thermostatted at 40°C.…”
Section: Chromatographic Details Lc-ms/ms Methods For the Determinatimentioning
confidence: 99%
“…We have previously reported a survey on MP levels in South African Sauvignon blanc wines and found levels of IBMP ranging from 0.40 to 44 ng/L (RSD of 102%) in 577 wines, while concentrations of IPMP and SBMP ranged from < 0.03 to 3.9 ng/L and < 0.03 to 3.2 ng/L respectively (Alberts et al, 2009). In the current study, 304 additional Sauvignon blanc wines were analysed.…”
Section: Introductionmentioning
confidence: 95%
See 3 more Smart Citations