2013
DOI: 10.1002/mrm.24920
|View full text |Cite
|
Sign up to set email alerts
|

Susceptibility map‐weighted imaging (SMWI) for neuroimaging

Abstract: SMWI presents an alternative contrast for susceptibility-based imaging. The validity of this method was demonstrated using in vivo data. This proposed method together with denoising allows high-quality reconstruction of susceptibility-weighted image of human brain in vivo.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
44
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 43 publications
(45 citation statements)
references
References 36 publications
1
44
0
Order By: Relevance
“…In addition, quantitative susceptibility mapping (QSM), which derives the susceptibility distribution from magnetic field variation by solving an inverse problem, makes it possible to evaluate the in vivo susceptibility changes quantitatively . Furthermore, the combination of SWI and QSM, the true susceptibility weighted imaging (tSWI), eliminates the orientation dependence in conventional SWI and improves the delineation of the vessels . However, neither SWI nor QSM is primarily used for in vivo detection of tiny arterioles, where vasculogenic neuropathology often begins .…”
mentioning
confidence: 99%
“…In addition, quantitative susceptibility mapping (QSM), which derives the susceptibility distribution from magnetic field variation by solving an inverse problem, makes it possible to evaluate the in vivo susceptibility changes quantitatively . Furthermore, the combination of SWI and QSM, the true susceptibility weighted imaging (tSWI), eliminates the orientation dependence in conventional SWI and improves the delineation of the vessels . However, neither SWI nor QSM is primarily used for in vivo detection of tiny arterioles, where vasculogenic neuropathology often begins .…”
mentioning
confidence: 99%
“…The resulting QSM was further processed to generate a QSM mask (S mask ) for susceptibility contrast weighting. The following scheme was used for the generation of the mask: Smask(χ)={0,(χthχ)/χth,1,χth<χ0<χ<χthotherwise where X is the quantitative susceptibility value (in units of ppm) calculated in Step 4 and X th is a paramagnetic threshold value. The threshold was determined later using the nigrosome 1 imaging data for an optimal CNR. Finally, the SMWI image was generated by multiplying the multiecho combined magnitude images with the QSM mask.…”
Section: Methodsmentioning
confidence: 99%
“…Alternative susceptibility contrast‐related approaches are GRE phase (or frequency) images and quantitative susceptibility mapping (QSM), both of which have shown a good sensitivity to magnetic susceptibility contrasts and have been widely applied in recent years . More recently, a new method that utilizes susceptibility weighting mask derived from QSM for the magnitude images has been proposed . This approach is similar to SWI but resolves the blooming artifacts of SWI and may potentially provide improved visualization of susceptibility variations.…”
mentioning
confidence: 99%
“…To further enhance the contrast of white matter structures, diamagnetic features predominant in white matter were extracted from the quantitative susceptibility maps and combined with the rescaled T 2 * maps, creating diamagnetic susceptibility map-weighted images (dSMWI) (Gho et al, 2014). The following equation was used in this process:…”
Section: Data Acquisitionmentioning
confidence: 99%