2016 IEEE 7th Power India International Conference (PIICON) 2016
DOI: 10.1109/poweri.2016.8077328
|View full text |Cite
|
Sign up to set email alerts
|

SVPWM based decoupled control of active and reactive power for single stage grid connected solar PV system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…In 2016, Sunny et al. [72] devised a control strategy for a “three‐level NPC inverter” in a GC‐PV. The suggested approach was indeed advantageous since it allows for independent control of active and reactive power.…”
Section: Literature Reviewmentioning
confidence: 99%
See 2 more Smart Citations
“…In 2016, Sunny et al. [72] devised a control strategy for a “three‐level NPC inverter” in a GC‐PV. The suggested approach was indeed advantageous since it allows for independent control of active and reactive power.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The microprocessor has been used as an implementation tool in [3] and [14]. In addition, PSCAD/EMTDC software in [32], DIgSILENT/PowerFactory in [34], dSPACE ds1104 based system in [42], DigSILENT software in [46] and OPAL‐RT's eMEGASIM and ePHASORSIM [86], PSIM software [59, 63, 64, 67, 70], MATLAB and PSIM co‐simulation platform [71], ARM CORTEX processor [75], DlgSI LENT/PowerFactory [60]: FORTRAN programming language [92], MATLAB/Simulation [1, 2, 4, 31, 39, 45, 48, 4958, 62, 65, 66, 68, 69, 72, 7374, 7785, 88, 91, 9394, 96, 97, 99, 100103, 107, 105, 106], software PSIM [89], DIgSILENT/PowerFactory [90], ETAP simulation platforms [29], DIgSILENT/PowerFactory [34], HiL tests in the PLECS settings [104], OPAL‐RT's eMEGASIM and ePHASORSIM [86], PSCAD/EMTDC [87] have been used as implementation tools.…”
Section: Analysis Of the Type Of Control Grid Code And Type Of Regsmentioning
confidence: 99%
See 1 more Smart Citation
“…using a single-stage converter architecture, are highly scarce and hard to find in related literature, though it is a feasible and interesting technology to be applied. For instance, in [8] a three-phase singlestage grid-connected photovoltaic system is controlled using a linear PI classic strategy with cross-coupling compensation, and in [9], the authors use a similar PI control for a singlestage 3-level NPC inverter used in an on-grid PV system. In [6], the single-stage grid-connected PV system is controlled using a PI control and the DC voltage with a voltage-oriented control.…”
Section: Introductionmentioning
confidence: 99%