With the further development of the automotive industry, the traditional vibration isolation method is difficult to meet the requirements for wide frequency bands under multiple operating conditions, the active control mount (ACM) is gradually paid attentions, and the control algorithm plays a decisive role. In this paper, the ACM with oscillating coil actuator (OCA) is taken as the object, and the comparative study of the control algorithms is performed to select the optimal one for ACM. Through the modelling of ACM, the design of controller and the system simulations, the force transmission rate is used to compare the vibration isolation performance of the nine control algorithms, which are least mean square (LMS) adaptive feedforward control, recursive least square (RLS) adaptive feedforward control, filtered reference signal LMS (FxLMS) adaptive control, linear quadratic regulator (LQR) optimal control, H2 control, H∞ control, proportional integral derivative (PID) feedback control, fuzzy control and fuzzy PID control. In summary, the FxLMS adaptive control algorithm has the better performance and the advantage of easier hardware implementation, and it can apply in ACMs.