2003
DOI: 10.1016/s1569-1993(02)00146-7
|View full text |Cite
|
Sign up to set email alerts
|

Sweat conductivity and chloride titration for cystic fibrosis diagnosis in 3834 subjects

Abstract: Sweat test is the standard for cystic fibrosis (CF) diagnosis. Conductivity is an alternative method not yet approved, in spite of its good correlation with chloride concentration. The aim was to assess the capacity of sweat conductivity to discriminate between CF and non-CF subjects. Automated measurements of conductivity and chloride concentration were carried out on the same sweat samples from subjects with clinical suspicion of CF. Sweat samples from 3,834 subjects, median age 1.8 years (range 1 month-54 y… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

5
52
0
7

Year Published

2005
2005
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(64 citation statements)
references
References 10 publications
5
52
0
7
Order By: Relevance
“…However, this method involves multiple steps for collection and analysis of the sweat sample and involves the risk of volumetric, gravimetric, condensate and evaporation errors in the procedure. In this context, the measurement of sweat conductivity is an increasingly used method because it is easier to perform and requires a smaller sample than QPIT [6].…”
Section: Introductionmentioning
confidence: 99%
“…However, this method involves multiple steps for collection and analysis of the sweat sample and involves the risk of volumetric, gravimetric, condensate and evaporation errors in the procedure. In this context, the measurement of sweat conductivity is an increasingly used method because it is easier to perform and requires a smaller sample than QPIT [6].…”
Section: Introductionmentioning
confidence: 99%
“…We decided to use a value of 90 mmol/L or higher as the cutoff point for the CF diagnosis based on the study by Lezana et al 20 These authors compared both sweat test …”
Section: Classic Test (Mmol/l)mentioning
confidence: 99%
“…[14][15][16][17][18][19][20][21] One of these methods includes the use of the device Macroduct ® -a sweat collection system, 22 through which sweat is collected into a plastic coil after stimulation by pilocarpine iontophoresis. Weighting and risk of evaporation are thus eliminated.…”
mentioning
confidence: 99%
“…Dessa forma, o valor de concentração derivado é levemente mais alto do que o valor obtido por análise química direta dos íons de cloreto e sódio, já que outros eletrólitos, além do Cl-e do Na+, são inevitavelmente incluídos. Contudo, alguns estudos já foram realizados, demonstrando que há uma correlação íntima e uma razoável concordância (especialmente para os valores mais baixos) entre os valores de equivalentes de NaCl medidos por análise de condutividade e aqueles obtidos pela análise química quantitativa de Cl-e Na+ [5][6][7][8] .…”
unclassified
“…Dados confirmatórios têm sido fornecidos com relação a precisão, exatidão e reprodutibilidade: com relação à reprodutibilidade, testes repetidos no mesmo indivíduo fornecem resultados semelhantes 7 . Dados confirmatórios também têm sido fornecidos com relação à sua sensibilidade (capacidade de identificar um paciente com CF como tendo a doença) e sua especificidade (capacidade de identificar um indivíduo saudável como sendo saudável) [5][6][7][8][9] . Contudo, há alguma incerteza com relação aos critérios adotados nos 89 0021-7557/10/86-02/89…”
unclassified