2017
DOI: 10.1016/j.polymer.2017.09.069
|View full text |Cite
|
Sign up to set email alerts
|

Swelling behaviors of proton exchange membranes in alcohols

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(12 citation statements)
references
References 67 publications
0
12
0
Order By: Relevance
“…However, swelling of Nafion when in contact with methanol has been observed in many studies 29,58,59 and was determined to be a rate‐limiting step in our previous work on methanol sorption into Nafion 28 . Therefore, an additional simulation in which the impact of swelling is explored was carried out.…”
Section: Methodsmentioning
confidence: 99%
“…However, swelling of Nafion when in contact with methanol has been observed in many studies 29,58,59 and was determined to be a rate‐limiting step in our previous work on methanol sorption into Nafion 28 . Therefore, an additional simulation in which the impact of swelling is explored was carried out.…”
Section: Methodsmentioning
confidence: 99%
“…The volume of the cables before and after being submerged were measured by the electronic densimeter (MDS-300, Alfa Mirage Co., Ltd., Osaka, Japan). 38 Based on this method, the R swell [−] is defined by eqn (3) : where V S and V 0 are the volumes of the cables after and before being submerged, respectively, as well as solubility and other properties of each solvent, the three most feasible solvents were selected. These were diethyl ether, methanol, and hexane.…”
Section: Methodsmentioning
confidence: 99%
“…The volume of the cables before and aer being submerged were measured by the electronic densimeter (MDS-300, Alfa Mirage Co., Ltd., Osaka, Japan). 38 Based on this method, the R swell [À] is dened by eqn 3:…”
Section: Solvent Selection Through Swelling and Solubility Tests Of Pvcmentioning
confidence: 99%
“…Measurement of swelling degree was performed by gravimetric method which was developed by Yi and Bae [32]. Samples of membranes (5 cm × 5 cm) were dried in oven at 50 °C temperature for 1 h then weighed as dry membrane weight (W 0 ).…”
Section: Membrane Swelling Degree Measurementmentioning
confidence: 99%
“…The peaks are analogous to the unique peak positions of TiO 2 , indicating that the TiO 2 particles are present in the CA membrane matrix. This method has been applied by earlier researchers to ascertain the presence of inorganic particles in the polymer membrane matrix [32,37].…”
Section: X-ray Diffraction Of Fabricated Membranementioning
confidence: 99%