1980
DOI: 10.1109/tpas.1980.319673
|View full text |Cite
|
Sign up to set email alerts
|

Switching Impulse Tests of EHV and UHV Transformers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

1981
1981
2016
2016

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…However, this test is not performed in the field for the impulse voltage generator huge and difficult to operate. IEC60060-3 propose using oscillating impulse voltage for equipment impulse withstand voltage test in field [1][2][3]. Oscillating impulse voltage has higher generation efficiency and close to the actual voltage waveform.…”
Section: Introductionmentioning
confidence: 99%
“…However, this test is not performed in the field for the impulse voltage generator huge and difficult to operate. IEC60060-3 propose using oscillating impulse voltage for equipment impulse withstand voltage test in field [1][2][3]. Oscillating impulse voltage has higher generation efficiency and close to the actual voltage waveform.…”
Section: Introductionmentioning
confidence: 99%
“…However, this test is not performed in the field for the impulse voltage generator huge and difficult to operate. To solve this problem, IEC60060-3 propose using oscillating impulse voltage for equipment on-site impulse withstand voltage test [1][2]. Oscillating impulse voltage has higher generation efficiency and close to the actual voltage waveform that electrical equipment bear.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, with electrical apparatus voltage levels is rising constantly, and the large demands for extra-high-voltage electrical apparatus, the traditional impulse voltage withstanding tests no longer meet the requirements for high voltage apparatus on-site tests. In order to ensure system reliability and wipe out the threats that the incipient faults from insulation inside the apparatus, it is recommended by relative standards to carry out oscillating impulse withstanding tests on electrical apparatus on-site tests, especially the oscillating switching impulse withstanding tests for power transformer [1]. The traditional generation device of double exponential wave is disadvantageous for experiments on-site because of its complex structure and low efficiency.…”
Section: Introductionmentioning
confidence: 99%