2021
DOI: 10.3390/diagnostics11050852
|View full text |Cite
|
Sign up to set email alerts
|

Symmetric Reconstruction of Functional Liver Segments and Cross-Individual Correspondence of Hepatectomy

Abstract: Accurate localization and analyses of functional liver segments are crucial in devising various surgical procedures, including hepatectomy. To this end, they require the extraction of a liver from computed tomography, and then the identification of resection correspondence between individuals. The first part is usually impeded by inherent deficiencies, as present in medical images, and vast anatomical variations across subjects. While the model-based approach is found viable to tackle both issues, it is often … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 51 publications
0
5
0
Order By: Relevance
“…Based on these datasets, a number of computerized methods were proposed to delineate a liver and benchmarked. Examples of the recent results are summarized in Table 1 [ 28 - 34 ]. Note that these studies may employ different accuracy metrics, e.g.…”
Section: Liver Segmentationmentioning
confidence: 99%
See 2 more Smart Citations
“…Based on these datasets, a number of computerized methods were proposed to delineate a liver and benchmarked. Examples of the recent results are summarized in Table 1 [ 28 - 34 ]. Note that these studies may employ different accuracy metrics, e.g.…”
Section: Liver Segmentationmentioning
confidence: 99%
“…, at initialization[ 23 , 41 ], during the process[ 42 , 43 ], in final adjustment[ 23 ], or with a combination thereof. The recent works are summarized in Table 2 [ 21 , 28 , 41 , 43 - 46 ].…”
Section: Liver Segmentationmentioning
confidence: 99%
See 1 more Smart Citation
“…Passing through any other point, light rays would deflect toward to or away from the optical center, c. In the calibration, these parameters were defined by a 33 camera matrix in the homogeneous coordinates, as expressed in Eq. (3).…”
Section: ) Intrinsic Parametersmentioning
confidence: 99%
“…[1] For instance, in computer aided diagnosis (CAD), 3D information on an anatomical shape and its peripherals, possibly with associated lesions, reconstructed from the tomographic scan of a patient [2], are of great clinical values. Presented with this information, a physician can make accurate diagnosis and prognosis of the disease, as well as can perform therapeutic intervention [3]. In remote sensing (RS), a digital elevation model (DEM) is used to assess topographic properties of an underlying terrain.…”
Section: Introductionmentioning
confidence: 99%