2007
DOI: 10.2202/1553-779x.1638
|View full text |Cite
|
Sign up to set email alerts
|

Synchronous Generators Modeling and Control Using the Framework of Individual Channel Analysis and Design: Part 1

Abstract: In this paper a comprehensive dynamical assessment of a high order synchronous generator plant is carried out using the Individual Channel Analysis and Design (ICAD) framework -a multivariable control engineering tool that allows robustness and system performance evaluations. The great benefits of ICAD are elucidated and contrasted to those provided by the long-time honored block diagram representations. Several models used for the small signal stability analysis of synchronous generators are evaluated under t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 15 publications
0
8
0
Order By: Relevance
“…Such phenomenon is caused by a resonance (lightly damped left hand plane pole -LHPP-pair) followed by an inverted resonance (lightly damped left hand plane zero -LHPZ-pair) present around 7 rad/s, which reduces the SG performance due to bandwidth limitation [22] . In the case of an SVC-upgraded system with damping capabilities, an auxiliary control loop is included [4,5] .…”
Section: Sg -Facts Device-upgraded Systemsmentioning
confidence: 99%
See 3 more Smart Citations
“…Such phenomenon is caused by a resonance (lightly damped left hand plane pole -LHPP-pair) followed by an inverted resonance (lightly damped left hand plane zero -LHPZ-pair) present around 7 rad/s, which reduces the SG performance due to bandwidth limitation [22] . In the case of an SVC-upgraded system with damping capabilities, an auxiliary control loop is included [4,5] .…”
Section: Sg -Facts Device-upgraded Systemsmentioning
confidence: 99%
“…on a 100 MVA base). The SG model corresponds to the fifth-order dynamic model presented in [22] . A TCSC with parameters of the Kayenta installation [24] is used.…”
Section: Sg -Facts Device-upgraded Systemsmentioning
confidence: 99%
See 2 more Smart Citations
“…Nevertheless, further research is required as the existing analysis tools, although applicable to large-scale systems (Kundur, et al, 1990), may lack physical transparency. As previously discussed by Leithead and O'Reilly (1992) and Ugalde, et al (2007), Individual Channel Analysis and Design (ICAD) provides an alternative and very insightful control-oriented framework with which to carry out small-signal stability assessments.…”
Section: Introductionmentioning
confidence: 99%