Synchrotron radiation external beam rotational radiotherapy of breast cancer: proof of principle

Abstract: The principle of rotational summation of the absorbed dose for breast cancer treatment with orthovoltage X-ray beams was proposed by J. Boone in 2012. Here, use of X-ray synchrotron radiation for image guided external beam rotational radiotherapy treatment of breast cancer is proposed. Tumor irradiation occurs with the patient in the prone position hosted on a rotating bed, with her breast hanging from a hole in the bed, which rotates around a vertical axis passing through the tumor site. Horizontal collimatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
6
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 47 publications
2
6
0
Order By: Relevance
“…Rotational kV-EBRT permitted a periphery-to-center dose ratio from 13% to 9% in homogeneous breast phantoms of 14-cm in diameter for beams of ~ 1 cm in size. Earlier the group investigated breast EBRT with a synchrotron beam termed synchrotron radiation rotational radiotherapy (SR 3 T) by means of MC simulations and experiments with the same 14-cm diameter phantom [48,49]. They performed Geant4 simulations and measurements with Gafchromic films, ionization chambers and TLD of phantom dose delivered with monoenergetic 60-175 keV synchrotron x-ray beams at the Australian Synchrotron IMBL.…”
Section: Proof-of-principle and Computational Models 341 Kilovoltamentioning
confidence: 99%
“…Rotational kV-EBRT permitted a periphery-to-center dose ratio from 13% to 9% in homogeneous breast phantoms of 14-cm in diameter for beams of ~ 1 cm in size. Earlier the group investigated breast EBRT with a synchrotron beam termed synchrotron radiation rotational radiotherapy (SR 3 T) by means of MC simulations and experiments with the same 14-cm diameter phantom [48,49]. They performed Geant4 simulations and measurements with Gafchromic films, ionization chambers and TLD of phantom dose delivered with monoenergetic 60-175 keV synchrotron x-ray beams at the Australian Synchrotron IMBL.…”
Section: Proof-of-principle and Computational Models 341 Kilovoltamentioning
confidence: 99%
“…Recently, we started the project SR 3 T (Synchrotron Radiation Rotational RadioTherapy) 24 , 25 , 26 for investigating breast RT using a kV photon beam and AuNPs dose enhancement. The proposed setup adopts a configuration in which the patients are in prone position with the breast hanging from a hole in the bed.…”
Section: Introductionmentioning
confidence: 99%
“…One potential solution is the use of lower energy kilovoltage (kV) x-rays in place of megavoltage (MV) x-rays from clinical linear accelerators (linacs), since the technology required to produce kV x-rays is less expensive and requires less infrastructure and less shielding to ensure a safe treatment environment. Recently, a number of groups have investigated various methods of adapting kV x-rays to treat deep-seated lesions [5][6][7][8]. Additionally, various research groups have studied the use of kilovoltage x-rays for stereotactic radiotherapy [9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%