2015
DOI: 10.1016/j.molstruc.2014.12.022
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis, characterization and pharmacological investigation of a new charge-transfer complex of 3-aminopyridinum-p-toluenesulfonate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(3 citation statements)
references
References 38 publications
0
3
0
Order By: Relevance
“…Cell data (dimensions) in Å a = 14.9230 (9) b = 6.5971 (4) c = 15.7552 (10) Volume in Å 3 1210 Formula (units) per unit cell 4 Density in g/cm 3 1.425 (10) Volume in Å 3 1210 Formula (units) per unit cell 4 Density in g/cm 3 1.425 2θ (max) in deg 50 The experimental density value of UGA was determined and correlated with the theoretical density value of UGA. These theoretical data were estimated using the formula [15], Density = MZ/NV where M, V and Z represents molar mass, volume and number of molecules in a one-unit cell respectively.…”
Section: Determination Of Single Crystal Xrdmentioning
confidence: 99%
“…Cell data (dimensions) in Å a = 14.9230 (9) b = 6.5971 (4) c = 15.7552 (10) Volume in Å 3 1210 Formula (units) per unit cell 4 Density in g/cm 3 1.425 (10) Volume in Å 3 1210 Formula (units) per unit cell 4 Density in g/cm 3 1.425 2θ (max) in deg 50 The experimental density value of UGA was determined and correlated with the theoretical density value of UGA. These theoretical data were estimated using the formula [15], Density = MZ/NV where M, V and Z represents molar mass, volume and number of molecules in a one-unit cell respectively.…”
Section: Determination Of Single Crystal Xrdmentioning
confidence: 99%
“…Z-scan experiments were carried out on bulk materials utilizing a continuous wave Nd:YAG laser beam (=1064 nm) as an excitation source, which was focused using a lens with a focal length of roughly 3.5 cm. The crystal sample was transferred along the axial direction of a focused laser beam through the focal region (+z to −z) in this investigation [24]. To get data regarding nonlinear absorption, open aperture Z-scan was used to get intensity dependent absorption without installing an aperture at the detector.…”
Section: Characterizationmentioning
confidence: 99%
“…Both the donor (AMMP) and its synthesized HB-CT complex were tested in vitro for antimicrobial activity against several microbes including Gram-positive bacteria, Gram-negative bacteria, and fungi. e microorganisms used in this study are commonly applied in research into new antimicrobial agents [54].…”
Section: Antimicrobial Activity Studiesmentioning
confidence: 99%