2015
DOI: 10.1039/c5nj00532a
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis of micro sphere-like bismuth nanoparticles by microwave assisted polyol method; designing a novel electrochemical nanosensor for ultra-trace measurement of Pb2+ ions

Abstract: Bi nanostructures were synthesized in the presence of propylene glycol as the solvent and surfactant through microwave method.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(15 citation statements)
references
References 72 publications
(58 reference statements)
0
15
0
Order By: Relevance
“…Copper hexacyanoferrate modified PGE for L-cysteine detection was obtained by cooper electrodeposition on PGE and subsequent immersion in a K 3 [Fe(CN) 6 ] solution [ 132 ]. PGE modified with MWCNTs (multiwall carbon nanotubes) and Bi-NS obtained by microwave-assisted polyol method were used for Pb(II) determination with a LD of 1.7 nM [ 202 ]. A sensitive composite sensor for hydrazine was developed by CV deposition of Cu-NS on MWCNTs modified PGE [ 149 ].…”
Section: Discussionmentioning
confidence: 99%
“…Copper hexacyanoferrate modified PGE for L-cysteine detection was obtained by cooper electrodeposition on PGE and subsequent immersion in a K 3 [Fe(CN) 6 ] solution [ 132 ]. PGE modified with MWCNTs (multiwall carbon nanotubes) and Bi-NS obtained by microwave-assisted polyol method were used for Pb(II) determination with a LD of 1.7 nM [ 202 ]. A sensitive composite sensor for hydrazine was developed by CV deposition of Cu-NS on MWCNTs modified PGE [ 149 ].…”
Section: Discussionmentioning
confidence: 99%
“…Recently, Safardoust‐Hojaghan et al. 83 prepared microsphere like Bi‐NP through microwave assisted polyol method. To improve the sensitivity, they modified the PGE with this Bi‐NP in combination with MWCNT by drop‐drying method.…”
Section: Nanomaterial‐modified Pge For Use In Electroanalysismentioning
confidence: 99%
“…The response was repeatable, with a response time less than 3 seconds for a 90% change in signal. Based on the CV and amperometric data and literature, we hypothesized that FRC (NaOCl/OCl - ) responds anodically with the PGE at an optimized oxidation potential of +1.50 V. In this experiment, sample de-aeration is not required, as the applied voltage of the amperometric experiments is well outside the voltage range of dissolved oxygen [ 46 ]. The limit of detection in these experiments was found to be 46 μM, which is lower compared to the reported values of 79 and 133 μM [ 47 ].…”
Section: Resultsmentioning
confidence: 99%