2022
DOI: 10.1007/s10854-022-08770-0
|View full text |Cite
|
Sign up to set email alerts
|

Synthesis, studies of 2-benzyl-amino-4-p-tolyl-6,7-di-hydro 5H-cyclo-penta–[b]pyridine-3 carbo-nitrile (BAPTDHCPCN) crystals for optical, photonic and mechano-electronic uses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 36 publications
0
9
0
Order By: Relevance
“…The sample was positioned between two metal electrodes during the two‐probe setup's AC conductivity measurements 67 . The dielectric measurements were carried out in the temperature range of 40–150°C and frequency range of 100–1 MHz, using LCR meter (AGILENT 4284A) with an accuracy of ±2% 68,69 . The real ( ε ′) part of the frequency‐dependent permittivity of the prepared films was determined using the below relation (1).…”
Section: Resultsmentioning
confidence: 99%
“…The sample was positioned between two metal electrodes during the two‐probe setup's AC conductivity measurements 67 . The dielectric measurements were carried out in the temperature range of 40–150°C and frequency range of 100–1 MHz, using LCR meter (AGILENT 4284A) with an accuracy of ±2% 68,69 . The real ( ε ′) part of the frequency‐dependent permittivity of the prepared films was determined using the below relation (1).…”
Section: Resultsmentioning
confidence: 99%
“…Using an Agilent 4284A LCR meter with an accuracy of ±2%, the produced PANI film's dielectric parameters were measured for various frequencies throughout a temperature range of 40–150°C 31,32 . The two‐probe setup, which is kept at a constant temperature using a processor controlled digital oven with an accuracy of ±0.05°C, has silver coated films put in between the silver electrodes.…”
Section: Resultsmentioning
confidence: 99%
“…Optimizing filler characteristics and concentrations is a critical step in getting the required electrical performance in polymer-based materials. 30 Using an Agilent 4284A LCR meter with an accuracy of ±2%, the produced PANI film's dielectric parameters were measured for various frequencies throughout a temperature range of 40-150 C. 31,32 The two-probe setup, which is kept at a constant temperature using a processor controlled digital oven with an accuracy of ±0.05 C, has silver coated films put in between the silver electrodes. Utilizing the following formulae, the real (ε 0 r ) part of the material's dielectric constant was determined.…”
Section: Electrical Analysismentioning
confidence: 99%
“…In general, it is a hardened process to make good-quality DGAMH crystalline specimens. It is premeditated for single crystal XRD study; molecular docking proviso; electric pulse properties; electronic studies; hardness profile; super lattice structure; Vander Waal's impacts; Supercell – Miller indices impact; nano-tubular generation of device constructing study [ [10] , [11] , [12] , [13] , [14] , [15] , [16] , [17] , [18] , [19] ].…”
Section: Introductionmentioning
confidence: 99%