2021
DOI: 10.1002/cjce.24120
|View full text |Cite
|
Sign up to set email alerts
|

Synthetic naphtha recovery from water streams: Vapour‐liquid–liquid equilibrium (VLLE) studies in a dynamic VL‐cell unit with high intensity mixing

Abstract: This work describes vapour pressure measurements of a water/synthetic naphtha mixture using a dynamic CREC-VL-Cell, designed to obtain reliable vapour measurements (P v sat,i ). The CREC-VL-Cell is used to measure vapour pressures for immiscible or partially miscible liquids, given its high multiphase mixing capability. Runs in the CREC-VL-Cell involve a dynamic method, operating with a set heating ramp, with continuous tracking of both saturation vapour pressure and temperature within the cell. This system al… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(23 citation statements)
references
References 36 publications
(30 reference statements)
1
13
0
Order By: Relevance
“…As shown in Table 1, n-Octane has properties similar to those of naphtha, which is one of the primary solvents used in bitumen processing. in previous works [10,11]. Furthermore, and regarding n-octane-water blends, there is already a significant body of data in the technical literature, as shown in Table 2.…”
Section: Specific Strategymentioning
confidence: 94%
See 4 more Smart Citations
“…As shown in Table 1, n-Octane has properties similar to those of naphtha, which is one of the primary solvents used in bitumen processing. in previous works [10,11]. Furthermore, and regarding n-octane-water blends, there is already a significant body of data in the technical literature, as shown in Table 2.…”
Section: Specific Strategymentioning
confidence: 94%
“…The Chemical Reactor Engineering Center (CREC) recently developed a CREC VL Cell which allows the measurements of VLL equilibrium (Figure 1) using a "dynamic method", with the temperature of the cell increasing progressively, using thermal ramp of 1.22 • C/min. As a result, every run provides a large amount of vapor-liquid equilibrium data (10 Hz), with the vapor pressure data being recorded at various temperatures, every 0.01 s. Additional explanations about the cell operation are reported in [10,11]. Data obtained from this dynamic method has been validated with static measurements [10,11].…”
Section: Crec Vapor Liquid Equilibrium Cellmentioning
confidence: 99%
See 3 more Smart Citations