2008
DOI: 10.1088/0957-0233/19/8/087002
|View full text |Cite
|
Sign up to set email alerts
|

System for measurement of low yield neutron pulses from D–D fusion reactions based upon a3He proportional counter

Abstract: A conventional neutron detection technique was adapted to measure low neutron yields from D-D fusion pulses. This method uses a 3 He proportional counter surrounded by a paraffin moderator. Electric signals generated in the 3 He tube are fed into a preamplifier. The output of the preamplifier is directly connected to a digital oscilloscope. The time-integrated signals represent the charge generated in the 3 He tube which is proportional to the total neutron yield. The integration time is determined by the prea… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
39
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 40 publications
(41 citation statements)
references
References 16 publications
(46 reference statements)
2
39
0
Order By: Relevance
“…2(e)], around the moment of the pinch formation, measurements of the neutron yield and electri- Fig. 4), for this shot, gives evidence of a neutron yield of 1.6 × 10 4 neutrons/shot, which is in agreement with measurements in a similar electrode configuration reported in [5] and [6]. From the electrical diagnostics with time resolution (see Fig.…”
Section: Experimental Observationssupporting
confidence: 85%
See 2 more Smart Citations
“…2(e)], around the moment of the pinch formation, measurements of the neutron yield and electri- Fig. 4), for this shot, gives evidence of a neutron yield of 1.6 × 10 4 neutrons/shot, which is in agreement with measurements in a similar electrode configuration reported in [5] and [6]. From the electrical diagnostics with time resolution (see Fig.…”
Section: Experimental Observationssupporting
confidence: 85%
“…The neutron production was measured by using two moderated 3 He-filled proportional counters ( 3 He tubes) according to the technique reported by Moreno et al [6]. Both detectors were arranged symmetrically side-on at a distance of 23.5 cm from the anode axis.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The circuit current is obtained by numerical integration of the signal of the current derivative. The neutron yield diagnostics consisted in two detection systems based on 3He proportional counters tubes moderated by paraffin wax, one located on the axis and the other located radially [39]. The 3He detection systems were calibrated in efficiency only, using as reference a standard isotopic fast-neutron source ( 252 Cf).…”
Section: Methodsmentioning
confidence: 99%
“…The data is an extended set of results from the experimental study presented in [20] and [46], where a new technique was especially developed to measure neutron pulses of low intensity [39], [40]. The model is able to explain the dependence of the neutron yield with the pressure and anode length, and suggests a physical interpretation of the empirical scaling laws commonly used in PF design.…”
mentioning
confidence: 99%