2011
DOI: 10.1061/(asce)st.1943-541x.0000300
|View full text |Cite
|
Sign up to set email alerts
|

System Identification Study of a 7-Story Full-Scale Building Slice Tested on the UCSD-NEES Shake Table

Abstract: A full-scale seven-story reinforced concrete building slice was tested on the unidirectional UCSD-NEES shake table during the period October 2005 -January 2006. A rectangular wall acted as the main lateral force resisting system of the building slice. The shake table tests were designed to damage the building progressively through four historical earthquake records. The objective of the seismic tests was to validate a new displacement-based design methodology for reinforced concrete shear wall building structu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
66
0
2

Year Published

2012
2012
2016
2016

Publication Types

Select...
7
2
1

Relationship

3
7

Authors

Journals

citations
Cited by 120 publications
(74 citation statements)
references
References 13 publications
6
66
0
2
Order By: Relevance
“…For these common bridges on elastomeric pad bearings, the first transverse vibration mode has a predominant contribution to the total response. Therefore, a natural frequency of 2.56 Hz for the first mode of the bridge model for system A was A c c e p t e d M a n u s c r i p t identified from the white noise excitations using multiple-reference natural excitation technique combined with eigen system realization algorithm (Moaveni et al 2010), which was close to the analytical results of 2.5 Hz. Moreover, on the basis of the measured acceleration responses recorded at the tables, the column middle, the column top, the bent cap, and the superstructure from lower to higher elevation levels, the first mode vibration shape of the bridge model identified from the white noise excitation (PGA=0.05g) was drown in Fig.…”
Section: Seismic Response Of System Amentioning
confidence: 94%
“…For these common bridges on elastomeric pad bearings, the first transverse vibration mode has a predominant contribution to the total response. Therefore, a natural frequency of 2.56 Hz for the first mode of the bridge model for system A was A c c e p t e d M a n u s c r i p t identified from the white noise excitations using multiple-reference natural excitation technique combined with eigen system realization algorithm (Moaveni et al 2010), which was close to the analytical results of 2.5 Hz. Moreover, on the basis of the measured acceleration responses recorded at the tables, the column middle, the column top, the bent cap, and the superstructure from lower to higher elevation levels, the first mode vibration shape of the bridge model identified from the white noise excitation (PGA=0.05g) was drown in Fig.…”
Section: Seismic Response Of System Amentioning
confidence: 94%
“…It discusses the extended Kalman filter, maximumlikelihood technique, recursive least-squares, and recursive instrumental-variable method. [35] and [48] present the seismic evaluation and design of moment resisting frame buildings using identification methods. They inspect several approaches, such as data-driven stochastic subspace identification, frequency domain decomposition, observer/Kalman filter identification, and general realization algorithm for system identification.…”
Section: Bidirectional Modeling Of Controlled Building Structuresmentioning
confidence: 99%
“…The test was conducted to investigate the dynamic response of the building, including the interaction between wall, slab, and gravity system of the building . In the experiment, four earthquake records were imposed on the building: 1) the longitudinal component of the 1971 San Fernando earthquake recorded at Van Nuys (EQ.1), which has Sa(T 1 ) of 0.32g, 2) the transverse component of the same Van Nuys record, which has Sa(T 1 ) of 0.75g, 3) the longitudinal component of the 1994 Northridge earthquake recorded at the Oxnard Boulevard station (EQ.3), which has Sa(T 1 ) of 0.60g , and 4) the 360° component of the 1994 Northridge earthquake recorded at the Sylmar station (EQ.4), which has Sa(T 1 ) of 1.38g (Moaveni et al 2011). …”
Section: Application Of the Proposed Methodologymentioning
confidence: 99%