1972
DOI: 10.1021/ac60322a016
|View full text |Cite
|
Sign up to set email alerts
|

Systematic approach to the study of aromatic hydrocarbons in heavy distillates and residues by elution adsorption chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

1974
1974
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(10 citation statements)
references
References 5 publications
0
10
0
Order By: Relevance
“…The Middle Eastern heavy oil was supplied by General Electric Global Research (Niskayuna, NY), and distillation was performed in a still pot as previously reported . Distillation cuts from South American extra heavy crude (482−533 °C), Middle Eastern heavy crude (510−538, 538−593, and residue 593 + °C) Mackay bitumen (550−600, 600−650, 650−700, and 700 + °C), were fractionated into n -C 7 asphaltenes and C 5–6 asphaltenes as noted below. ,,, High-performance liquid chromatography-grade n -heptane ( n -C 7 ), n -pentane ( n -C 5 ), and toluene (J.T. Baker Chemicals, Phillipsburg, NJ, U.S.A.) and Whatman #2 filter paper (30 μm, 150 mm diameter, GE Healthcare Bio-Sciences, Pittsburgh, PA, U.S.A.) were used as received.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The Middle Eastern heavy oil was supplied by General Electric Global Research (Niskayuna, NY), and distillation was performed in a still pot as previously reported . Distillation cuts from South American extra heavy crude (482−533 °C), Middle Eastern heavy crude (510−538, 538−593, and residue 593 + °C) Mackay bitumen (550−600, 600−650, 650−700, and 700 + °C), were fractionated into n -C 7 asphaltenes and C 5–6 asphaltenes as noted below. ,,, High-performance liquid chromatography-grade n -heptane ( n -C 7 ), n -pentane ( n -C 5 ), and toluene (J.T. Baker Chemicals, Phillipsburg, NJ, U.S.A.) and Whatman #2 filter paper (30 μm, 150 mm diameter, GE Healthcare Bio-Sciences, Pittsburgh, PA, U.S.A.) were used as received.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…Products from the reactions were analyzed using a combination of the following: (1) GLC using a 100-ft SCOT capillary column, (2) preparative liquid chromatography using basic alumina (Jewell et al, 1972), (3) preparative HPLC using a 10 mm X 50 cm column packed with Lichrosorb (silica) and the solvent n-hexane, at a flow rate of 9.0 mL/min, (4) 13C NMR using a Varian CFT-20 instrument, and ( 5 ) GLC-mass spectra using a Du Pont 491 instrument. Products from the reactions were analyzed using a combination of the following: (1) GLC using a 100-ft SCOT capillary column, (2) preparative liquid chromatography using basic alumina (Jewell et al, 1972), (3) preparative HPLC using a 10 mm X 50 cm column packed with Lichrosorb (silica) and the solvent n-hexane, at a flow rate of 9.0 mL/min, (4) 13C NMR using a Varian CFT-20 instrument, and ( 5 ) GLC-mass spectra using a Du Pont 491 instrument.…”
Section: Methodsmentioning
confidence: 99%
“…Specifically labeled 13C-octahydrophenanthrene was synthesized by Dr. E. J. Eisenbraun, details of which will be described elsewhere. Products from the reactions were analyzed using a combination of the following: (1) GLC using a 100-ft SCOT capillary column, (2) preparative liquid chromatography using basic alumina (Jewell et al, 1972), (3) preparative HPLC using a 10 mm X 50 cm column packed with Lichrosorb (silica) and the solvent n-hexane, at a flow rate of 9.0 mL/min, (4) 13C NMR using a Varían and (5) GLC-mass spectra using a Du Pont 491 instrument.…”
Section: Methodsmentioning
confidence: 99%
“…When aromatics from high sulfur vacuum residuals are separated on zero per cent water-alumina by the method of Jewell, et al (1972a), one observes that: (1) only traces of sulfur-free monoaromatics are present; (2) most of the aromatic structures have two or three rings; and (3) the sulfur is concentrated in the di + triaromatic fractions. The cut-points in these aromatic separations are made by on-line UAD at 254, 313, and 365-nm wavelengths.…”
Section: Discussion Of Resultsmentioning
confidence: 99%