1991
DOI: 10.1007/bf00393876
|View full text |Cite
|
Sign up to set email alerts
|

Systemic effects of implanted prostheses made of cobalt-chromium alloys

Abstract: Systemic effects of Co-Cr alloy/polyethylene hip joint prostheses were investigated using instrumental neutron activation to determine the concentrations of up to 16 elements. First, in a prospective study whole blood and serum taken from 10 patients from 1 day before to 90 days after implantation were analyzed. Secondly, in a retrospective study whole blood and serum from 23 patients who had had prostheses in place for up to 18 years were analyzed. For comparison, normal trace element levels in humans were de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
46
0
1

Year Published

1991
1991
2013
2013

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 129 publications
(49 citation statements)
references
References 21 publications
2
46
0
1
Order By: Relevance
“…Elevation of serum metal levels after primary total hip arthroplasty is well-documented 4,12,[14][15][16][17] , and several studies have investigated the serum levels of cobalt and chromium after joint arthroplasty [14][15][16]18,19 . However, there is limited information available regarding the long-term impact of primary metal-onpolyethylene total hip replacements on the serum concentrations of metals, particularly for serum titanium in titanium-containing implants 4,12,20,21 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Elevation of serum metal levels after primary total hip arthroplasty is well-documented 4,12,[14][15][16][17] , and several studies have investigated the serum levels of cobalt and chromium after joint arthroplasty [14][15][16]18,19 . However, there is limited information available regarding the long-term impact of primary metal-onpolyethylene total hip replacements on the serum concentrations of metals, particularly for serum titanium in titanium-containing implants 4,12,20,21 .…”
Section: Discussionmentioning
confidence: 99%
“…One of the general limitations in the literature regarding metal ion concentrations is the wide variability in how measurements are gathered, analyzed, and reported, thus making comparisons between studies difficult 18 . Even within studies there is substantial technical difficulty in ensuring that samples are drawn, processed, and analyzed in the exact same manner for consistency of results.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the cause-and-effect relationship between metal wear debris and local or systemic disease has not been conclusively proved, complications from metal wear products are a subject for concern [18,31,35]. Any metal-on-metal bearing combination used in joint replacements must, therefore, be designed and manufactured in such a way as to produce minimal debris.…”
Section: Discussionmentioning
confidence: 99%
“…Gradual mobilization of metals from CoCrMo prostheses has also been documented in patients, based upon analyses of Co or Cr concentrations in serum or urine (Coleman et al 1973, Miehlke et al 1981, Pazzaglia et al 1986 and detection of Co or Cr in periprosthetic soft tissues and distant organs (Emn6us et al 1961, Michel et al 1984, 1991. The release of metals from implanted prostheses metal has been attributed to corrosion, wear, or a combination of these Factors.…”
Section: Discussionmentioning
confidence: 99%