2008
DOI: 10.1002/mrc.2228
|View full text |Cite
|
Sign up to set email alerts
|

T1 relaxation measurement with solvent suppression

Abstract: Three solvent-suppression pulse sequences of varying complexity were incorporated into the standard inversion recovery pulse program and experimentally evaluated. The least complex suppression sequence involves a composite 90 degrees pulse. A more complex sequence utilizes an excitation sculpting sequence requiring pulsed field gradients, and the most complex sequence incorporates an excitation sculpting sequence with selective rf pulses and gradient pulses. The quality of the spectral data and the accuracy of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…We applied a slightly modified version of the excitation sculpting (ES) sequence that removes the water from the process and allows smooth and precise measurement of T1. Our method is closely related to variants published recently [23] ; however, we fully avoided presaturation of the water signal by applying an effective 360…”
Section: T1 Measurementsmentioning
confidence: 98%
“…We applied a slightly modified version of the excitation sculpting (ES) sequence that removes the water from the process and allows smooth and precise measurement of T1. Our method is closely related to variants published recently [23] ; however, we fully avoided presaturation of the water signal by applying an effective 360…”
Section: T1 Measurementsmentioning
confidence: 98%
“…The integration ranges for each of the nine signals were chosen as in our previous T 1 study where we were using the same chemical sample system. [1] The T 2 values from Sample 1 are summarized in Table 1. As one might expect from the qualitative assessment of the waterfall plots, agreement with the Standard CPMG pulse program is the least for Signals 1 and 2, where the best agreement is observed for the Just Presat pulse program, which we understand to be a result of having the narrowest gap in the excitation profile in www.interscience.wiley.com/journal/mrc The same trends are also observed for the T 2 values obtained from Samples 2 and 3, which are summarized in Tables 2 and 3, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…[1] Despite that solvent suppression has been a continuing topic of scrutiny in NMR spectroscopy [2 -6] and a number of reviews have appeared on this subject, [7 -10] literature on solvent suppression during relaxation measurements is virtually absent. Besides our previous report, [1] we are aware of only one other study [11] on solvent suppression during T 1 relaxation measurements and none for solvent suppression during T 2 relaxation measurements.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Such solvent suppression pulse sequences have also been incorporated into many common 1D and 2D experiments. In fact, the authors have incorporated them recently in relaxation measurements (Hoffmann et al, 2008b. For an in-depth coverage on the issues related to solvent suppression in NMR spectroscopy, the interested reader is referred to a recent review (Zheng and Price, 2010).…”
Section: Considerations For Spectral Acquisitionmentioning
confidence: 99%