2017
DOI: 10.1016/j.rser.2017.03.033
|View full text |Cite
|
Sign up to set email alerts
|

Table-based DPC for grid connected VSC under unbalanced and distorted grid voltages: Review and optimal method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
28
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(28 citation statements)
references
References 55 publications
0
28
0
Order By: Relevance
“…5 shows a typical control scheme for the grid‐connected mode involving a secondary communication‐based layer. This section summarises the available literature [14, 15, 16, 17, 20, 24, 26, 162, 219, 226–366] on unbalance mitigation in the grid‐connected scenario of both single and multiple inverters.…”
Section: Unbalance Mitigation In the Grid‐connected Modementioning
confidence: 99%
See 1 more Smart Citation
“…5 shows a typical control scheme for the grid‐connected mode involving a secondary communication‐based layer. This section summarises the available literature [14, 15, 16, 17, 20, 24, 26, 162, 219, 226–366] on unbalance mitigation in the grid‐connected scenario of both single and multiple inverters.…”
Section: Unbalance Mitigation In the Grid‐connected Modementioning
confidence: 99%
“…A review and comparison of the various approaches for table‐based DPC for grid‐connected inverters, i.e. voltage‐based DPC, resilient voltage‐based DPC, virtual flux‐based DPC (VF‐DPC), and the proposed resilient VF‐DPC is provided in [237], while a new DPC strategy achieving symmetrical grid currents under unbalanced grid voltage is discussed in [14]. An enhanced IPT‐based control is compared for its performance versus a CPT‐based approach in [15] for unbalance compensation.…”
Section: Unbalance Mitigation In the Grid‐connected Modementioning
confidence: 99%
“…To achieve the constant switching frequency, a modified DTC strategy based on space vector modulation was developed [18], [19]. Based on the DTC strategy concept, the direct power control (DPC) was developed for grid-connected VSCs [20]- [22]. In [20] and [21], a look-up-table (LUT)-DPC was developed, where the proper switching states are selected from a predefined optimal switching table based on the instantaneous errors of active and reactive powers and the angular position of the VSC terminal voltage.…”
mentioning
confidence: 99%
“…Table 2, the THD of the currents is different for each condition of the applied voltages. The more unbalance in grid voltage, the more increase in THD we get, however it is not affected by the harmonic content in voltage as mentioned in [9].…”
Section: Modeling Of Pmsg the Model Of Pmsg In D−q Transformation Ismentioning
confidence: 94%
“…5) shows that the new algorithm responds faster than traditional control. The active and instantaneous reactive powers are observed in the (power observer block) by the measurement of the line current and the observation of the virtual flux components in equation [9]. Instant active and reactive powers can be estimated as…”
Section: Modeling Of Pmsg the Model Of Pmsg In D−q Transformation Ismentioning
confidence: 99%