1975
DOI: 10.2172/4033019
|View full text |Cite
|
Sign up to set email alerts
|

Tables and graphs of photon interaction cross sections from 1.0 keV to 100 MeV derived from the LLL Evaluated Nuclear Data Library

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
85
0

Year Published

1979
1979
2020
2020

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 86 publications
(88 citation statements)
references
References 0 publications
3
85
0
Order By: Relevance
“…Photoatomic interaction cross-sections from Scofield, 64 Hubbell et al, 65 and Hubbell and Øverbø 66 were used. The MC code uses NIST XCOM mass-energy absorption coefficients from Hubbell and Seltzer, 56 and atomic data from Plechaty et al 67 were used for characteristic x-ray generation. Both Anagnostopoulos et al and Karaiskos et al used CON L = 0.34 cm for their derivations of brachytherapy dosimetry parameters.…”
Section: A33 Model I25s18 Anisotropy Functionsmentioning
confidence: 99%
“…Photoatomic interaction cross-sections from Scofield, 64 Hubbell et al, 65 and Hubbell and Øverbø 66 were used. The MC code uses NIST XCOM mass-energy absorption coefficients from Hubbell and Seltzer, 56 and atomic data from Plechaty et al 67 were used for characteristic x-ray generation. Both Anagnostopoulos et al and Karaiskos et al used CON L = 0.34 cm for their derivations of brachytherapy dosimetry parameters.…”
Section: A33 Model I25s18 Anisotropy Functionsmentioning
confidence: 99%
“…where 0.324 is the value of J.L'(Jl+T\) for BGO which preserves the normalization of 1000 for BGO, f is the packing fraction of the powder (the ratio of the powder density to the crystal density), and x is the depth in the powder. Note that the relationship between I and 10 does not depend on f. We used known x-ray cross sections [7] and densities to determine Jl and p, and chose a value of T\ for best agreement between the intensity of the known scintillators and their accepted values relative to BGO. Although T\ undoubtedly varies from sample to sample, we used the value T\-l = 0.01 mm for all the inorganic powders and the agreement was within a factor of three for BaF2, CeF3, and CaW04.…”
Section: Correcting the Total Fluorescent Output For Absorptionmentioning
confidence: 99%
“…In the high field limit, it was found that the resulting cross section for the nonlinear process had a value slightly greater than the total single-photon cross section [26,27] [29].…”
mentioning
confidence: 98%