2004
DOI: 10.1007/s00604-003-0169-z
|View full text |Cite
|
Sign up to set email alerts
|

?-TaN as a Reference Material for the Determination of High Nitrogen Contents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 0 publications
0
13
0
Order By: Relevance
“…The stoichiometric e-TaN (with an O-content of 0.01-0.05 wt% in the bulk) was chosen as the standard for N and Ta because i) it consists of the same two main elements as the high-pressure products, ii) it is a ''line compound'', i.e., a Ta-nitride with a very narrow homogeneity range of less than 0.4 at% of N, and iii) it has a high N:Ta ratio when compared with other certified N standards. [36] To cross-check the nitrogen analysis with a different standard, we also used stoichiometric Ce 3 Si 6 N 11 . [37] Bulk Ta 2 O 5 was chosen as the oxygen standard in order to keep matrix effects as small as possible.…”
Section: Full Papermentioning
confidence: 99%
“…The stoichiometric e-TaN (with an O-content of 0.01-0.05 wt% in the bulk) was chosen as the standard for N and Ta because i) it consists of the same two main elements as the high-pressure products, ii) it is a ''line compound'', i.e., a Ta-nitride with a very narrow homogeneity range of less than 0.4 at% of N, and iii) it has a high N:Ta ratio when compared with other certified N standards. [36] To cross-check the nitrogen analysis with a different standard, we also used stoichiometric Ce 3 Si 6 N 11 . [37] Bulk Ta 2 O 5 was chosen as the oxygen standard in order to keep matrix effects as small as possible.…”
Section: Full Papermentioning
confidence: 99%
“…It is easy to find standards with ppm and tens of ppm in steel, but at the percent level Si 3 N 4 (N, 39.94 wt%) is probably one the rare marketed nitride standards. At lower percentages, ε-TaN (N 7.18 wt%) remains a convenient calibration standard [ 26 ]. This phase is prepared by reaction in an autoclave from high-purity tantalum foil under N 2 pressure at high temperatures (close to 1900 °C) and has the main advantage of presenting a defined nitrogen content.…”
Section: Chemical Methodsmentioning
confidence: 99%
“…Nitrogen was measured as N 2 by thermal conductivity and oxygen as CO 2 by infrared detection. The apparatus was calibrated using N 2 and CO 2 gas (purity ≥99.95%) as well as ε-TaN as a nitrogen standard . At least two analyses were performed in the same conditions for each sample.…”
Section: Methodsmentioning