2004
DOI: 10.1016/j.jpowsour.2004.03.028
|View full text |Cite
|
Sign up to set email alerts
|

Tangential and normal conductivities of Nafion® membranes used in polymer electrolyte fuel cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

12
105
5

Year Published

2005
2005
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 152 publications
(122 citation statements)
references
References 27 publications
12
105
5
Order By: Relevance
“…In contrast, Pozio et al took the membrane thickness to be the nominal value of 127 µm and only soaked the N115 MEAs in water after hot pressing ( = 10), which, as stated by these authors, would not fully hydrate the N115 membrane to the expanded E-form with a restored hydrophilic cluster structure. However, the values of conductivities obtained in this study for N115 correlate well with values for fully hydrated ( = 22 -23) Nafion ® membranes obtained from previous studies using different normal and tangential methods as reviewed in Tables 1 and 2 in Reference [28].…”
Section: The Conductivity Of Fully Hydrated Nafion ® -115 (N115) As Bsupporting
confidence: 87%
See 4 more Smart Citations
“…In contrast, Pozio et al took the membrane thickness to be the nominal value of 127 µm and only soaked the N115 MEAs in water after hot pressing ( = 10), which, as stated by these authors, would not fully hydrate the N115 membrane to the expanded E-form with a restored hydrophilic cluster structure. However, the values of conductivities obtained in this study for N115 correlate well with values for fully hydrated ( = 22 -23) Nafion ® membranes obtained from previous studies using different normal and tangential methods as reviewed in Tables 1 and 2 in Reference [28].…”
Section: The Conductivity Of Fully Hydrated Nafion ® -115 (N115) As Bsupporting
confidence: 87%
“…As the sample standard deviation over the three samples is the same magnitude as the CIEs, there is no significant variability between the MEAs of each sample of N115 when measuring the conductivities using this method and cell setup. The conductivity values obtained are much larger that those obtained by Pozio et al for N115 ( = 0.045 ± 0.004 S cm -1 at 65°C) [28]. This can be explained by the fact that in this study the N115 MEAs were boiled for 2 h in water to reproduce the fully hydrated expanded form after hot-pressing and that the membrane thickness was taken as 140 ± 9 µm.…”
Section: The Conductivity Of Fully Hydrated Nafion ® -115 (N115) As Bcontrasting
confidence: 62%
See 3 more Smart Citations