2023
DOI: 10.1021/acs.est.3c00190
|View full text |Cite
|
Sign up to set email alerts
|

Targeted Decomplexation of Metal Complexes for Efficient Metal Recovery by Ozone/Percarbonate

Abstract: Traditional methods cannot efficiently recover Cu from Cu(II)− EDTA wastewater and encounter the formation of secondary contaminants. In this study, an ozone/percarbonate (O 3 /SPC) process was proposed to efficiently decomplex Cu(II)−EDTA and simultaneously recover Cu. The results demonstrate that the O 3 /SPC process achieves 100% recovery of Cu with the corresponding k obs value of 0.103 min −1 compared with the typical • OH-based O 3 /H 2 O 2 process (81.2%, 0.042 min −1 ). The carbonate radical anion (CO … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 39 publications
(12 citation statements)
references
References 60 publications
0
12
0
Order By: Relevance
“…DFT calculations were performed to determine the work function of the catalysts to probe the flow and charge transfer between the interfaces. 29,30 As shown in Figure 3b, the calculation results exhibit BiVO 4 with high-level work function (6.88 eV) while BiOBr results in a lower work function of 5.60 eV. Combined with the test of the band gap, the initial state of the band structure diagram of BiVO 4 and BiOBr before contact is shown in Figure 3c, left.…”
Section: Resultsmentioning
confidence: 81%
See 1 more Smart Citation
“…DFT calculations were performed to determine the work function of the catalysts to probe the flow and charge transfer between the interfaces. 29,30 As shown in Figure 3b, the calculation results exhibit BiVO 4 with high-level work function (6.88 eV) while BiOBr results in a lower work function of 5.60 eV. Combined with the test of the band gap, the initial state of the band structure diagram of BiVO 4 and BiOBr before contact is shown in Figure 3c, left.…”
Section: Resultsmentioning
confidence: 81%
“…As shown in Figure a, the high-resolution XPS pattern of O 1s revealed the signals belonging to the Bi–O bond in BiOBr/BiVO 4 were shifted to higher binding energy compared with those in BiOBr while showing an opposite trend with BiVO 4 , indicating a lower electron density around BiVO 4 in hybrids. , Therefore, it can be speculated that there existed a strong electron interaction that induced the electron transfer from BiOBr to BiVO 4 . DFT calculations were performed to determine the work function of the catalysts to probe the flow and charge transfer between the interfaces. , As shown in Figure b, the calculation results exhibit BiVO 4 with high-level work function (6.88 eV) while BiOBr results in a lower work function of 5.60 eV. Combined with the test of the band gap, the initial state of the band structure diagram of BiVO 4 and BiOBr before contact is shown in Figure c, left.…”
Section: Resultsmentioning
confidence: 99%
“…The experimental solutions used in this study were all prepared with Milli-Q ultrapure water (with a specific conductivity of >18.2 MΩ cm). The strain used for toxicity testing was Vibrio qinghaiensis sp.-Q67 from the Department of Biology at East China Normal University . The real Cl–Py wastewater was collected from a company in Jiangxi Province (Cl–Py: 31.4 mg L –1 , NO 3 – : 75.5 mg L –1 , NH 4 + : 12.0 mg L –1 , Cl – : 21.6 mg L –1 , COD: 212.5 mg L –1 , pH = 8.4).…”
Section: Methodsmentioning
confidence: 99%
“…The strain used for toxicity testing was Vibrio qinghaiensis sp.-Q67 from the Department of Biology at East China Normal University. 28 The real Cl−Py wastewater was collected from a company in Jiangxi Province (Cl−Py: 31.4 mg L −1 , NO 3 − : 75.5 mg L −1 , NH 4 + : 12.0 mg L −1 , Cl − : 21.6 mg L −1 , COD: 212.5 mg L −1 , pH = 8.4).…”
Section: ■ Introductionmentioning
confidence: 99%
“…38 Electron paramagnetic resonance (EPR) measurements were performed for the detection of cOH and SO 4 c − . 39 DMPO was used as the capturing agent for cOH and SO 4 c − . 38 The DMPO-containing electrolyte samples were used in electrochemical samples.…”
Section: On-site Tracking Of Rosmentioning
confidence: 99%