2018
DOI: 10.1016/j.chemosphere.2017.10.122
|View full text |Cite
|
Sign up to set email alerts
|

TBBPA disposition and kinetics in pregnant and nursing Wistar Han IGS rats

Abstract: Tetrabromobisphenol-A (TBBPA) is a brominated flame retardant (BFR) commonly used in electronics to meet fire safety standards and has the largest worldwide production of any BFR. TBBPA has been detected in human breast milk and maternal/cord serum, indicating exposure to mothers, fetuses, and breastfeeding newborns although exposure to fetuses and newborns is poorly understood. Pregnant or nursing Wistar Han IGS rats were administered [C]-TBBPA in a single dose (25 mg/kg, 2.5 μCi/kg) and euthanized between 0.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 31 publications
(32 citation statements)
references
References 35 publications
1
31
0
Order By: Relevance
“…The electrochemical behavior of modified electrode was investigated in 10 mL of 0.2 M phosphate buffer solution (PBS) of pH 7.0, containing 5 mM K 4 [Fe(CN) 6 6 ] using Cyclic voltammetry (CV) and A.C. impedance (IMP). The CV measurement was carried out from À0.2 V to + 0.6 V (vs. SCE) with a scan rate of 50 mV · s À1 .…”
Section: Electrochemical Measurementmentioning
confidence: 99%
See 4 more Smart Citations
“…The electrochemical behavior of modified electrode was investigated in 10 mL of 0.2 M phosphate buffer solution (PBS) of pH 7.0, containing 5 mM K 4 [Fe(CN) 6 6 ] using Cyclic voltammetry (CV) and A.C. impedance (IMP). The CV measurement was carried out from À0.2 V to + 0.6 V (vs. SCE) with a scan rate of 50 mV · s À1 .…”
Section: Electrochemical Measurementmentioning
confidence: 99%
“…The CV measurement was carried out from À0.2 V to + 0.6 V (vs. SCE) with a scan rate of 50 mV · s À1 . The calibration curves of prepared sensor and sample analysis were investigated using differential pulse strippinig voltammetry (DPSV) in 10 mL of 0.2 M phosphate buffer solution (PBS) of pH 7.0 containing 5 mM K 4 [Fe(CN) 6 6 ] and different concentration of TBBPA. The optimization of experimental parameters were measured with differential pulse voltammetry (DPV) in potential range of À0.2 V to + 0.6 V (vs. SCE) with the support electrolyte of 10 mL of 0.2 M phosphate buffer solution (PBS) of pH 7.0, containing 5 mM K 4 [Fe(CN) 6 ]/K 3 [Fe(CN) 6 ].…”
Section: Electrochemical Measurementmentioning
confidence: 99%
See 3 more Smart Citations