2023
DOI: 10.1016/j.aca.2023.341281
|View full text |Cite
|
Sign up to set email alerts
|

Tear-based MMP-9 detection: A rapid antigen test for ocular inflammatory disorders using vanadium disulfide nanowires assisted chemi-resistive biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 57 publications
0
3
0
Order By: Relevance
“…To achieve a repeatable biosensor response, notably, the composite-DMF dispersion was dropped cast in 1.5 μL volume at three steps (0.5 μL × 3) on top of the IDEs to mitigate the device variability . Additionally, during the drop-casting steps, the biosensor’s substrate was heated at 60 °C, reported effective in variability reduction . Finally, the response of the biosensor device is evaluated from the calibration curve prepared from the experiments with known concentrations of the control samples.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…To achieve a repeatable biosensor response, notably, the composite-DMF dispersion was dropped cast in 1.5 μL volume at three steps (0.5 μL × 3) on top of the IDEs to mitigate the device variability . Additionally, during the drop-casting steps, the biosensor’s substrate was heated at 60 °C, reported effective in variability reduction . Finally, the response of the biosensor device is evaluated from the calibration curve prepared from the experiments with known concentrations of the control samples.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…36 Additionally, during the drop-casting steps, the biosensor's substrate was heated at 60 °C, reported effective in variability reduction. 37 Finally, the response of the biosensor device is evaluated from the calibration curve prepared from the experiments with known concentrations of the control samples. For preparing the calibration curve, the current values obtained for the selected voltage range with the voltage selection algorithm had been used.…”
Section: Synthesis Of Cnt-zno Compositementioning
confidence: 99%
“…These powders resulted in different morphology (section 3.1: characterization of VS 2 ), as 2D nanostructure showed superior electrochemical performance-it was chosen for the construction of biosensors. This methodology of 2D VS 2 nanosheet synthesis with some modifications has been reported in previous works [31][32][33].…”
Section: Synthesis Of 2d Vs 2 Nanosheetsmentioning
confidence: 99%