Tear Strength Analysis of MDX4-4210 and A-2186 Silicones with Different Intrinsic Pigments Incorporated by Mechanical and Industrial Methods

Abstract: Objective. The aim of this study was to evaluate the tear strength of MDX4-4210 and A-2186 silicones with different intrinsic pigments incorporated by mechanical and industrial methods, comparing nonaged and aged groups. Materials and Methods. Twenty-four groups were created according to the American Society for Testing and Materials D-624/type C, half nonaged and half aged (n = 10): bronze mechanical MDX4-4210, bronze industrial MDX4-4210, black mechanical MDX4-4210, black industrial MDX4-4210, pink mechanica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
73
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 7 publications
(74 citation statements)
references
References 18 publications
(47 reference statements)
1
73
0
Order By: Relevance
“…7,14,22 The extrinsic factors like ultraviolet radiation, daily handling, temperature, air pollution, water absorption, and adsorption can also cause degradation of a silicone. [1][2][3]5,7,8,10,[13][14][15][16][17]22 According to Goiato et al 9 and Mancuso et al, 15 the use of 1,008 hours of accelerated aging (in vitro) corresponds to 1 year of constant use of a silicone prosthesis by the patient. 9,15 Therefore, if a silicone prosthesis generally has a maximum clinical durability of 1 year, 2,[4][5][6][7]10,13,15 aging for 1,008 hours (in vitro) is sufficient to simulate a clinical situation.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…7,14,22 The extrinsic factors like ultraviolet radiation, daily handling, temperature, air pollution, water absorption, and adsorption can also cause degradation of a silicone. [1][2][3]5,7,8,10,[13][14][15][16][17]22 According to Goiato et al 9 and Mancuso et al, 15 the use of 1,008 hours of accelerated aging (in vitro) corresponds to 1 year of constant use of a silicone prosthesis by the patient. 9,15 Therefore, if a silicone prosthesis generally has a maximum clinical durability of 1 year, 2,[4][5][6][7]10,13,15 aging for 1,008 hours (in vitro) is sufficient to simulate a clinical situation.…”
Section: Discussionmentioning
confidence: 99%
“…5,7,9,13,14,16,17 The intrinsic opacifier (ZnO) corresponded to 2% of the silicone weight. 3 The silicone was manipulated at 23 ± 2°C with a relative humidity 5,[7][8][9]13,14,16,17 of 50 ± 10%. 14,16,17 The base and catalyst paste were mixed according to the manufacturer's recommendations until the paste becomes homogeneous.…”
Section: Preparation Of Samplesmentioning
confidence: 99%
See 3 more Smart Citations