2006
DOI: 10.1016/j.seppur.2006.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Technical and economic analysis of electrocoagulation for the treatment of poultry slaughterhouse wastewater

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
51
0
16

Year Published

2007
2007
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 128 publications
(69 citation statements)
references
References 33 publications
2
51
0
16
Order By: Relevance
“…The electrodes were washed thoroughly with water to remove any solid residues on the surfaces, washed with acetone to remove surface grease, and the impurities on the aluminum electrode surfaces which were removed by dipping for 5min in a HCl solution (35%), dried and weight. At the end of the run, the electrodes were washed again and reweighed to calculate sacrificial electrode consumptions (BAYRAMOGLU et al, 2006).…”
Section: Methodsmentioning
confidence: 99%
“…The electrodes were washed thoroughly with water to remove any solid residues on the surfaces, washed with acetone to remove surface grease, and the impurities on the aluminum electrode surfaces which were removed by dipping for 5min in a HCl solution (35%), dried and weight. At the end of the run, the electrodes were washed again and reweighed to calculate sacrificial electrode consumptions (BAYRAMOGLU et al, 2006).…”
Section: Methodsmentioning
confidence: 99%
“…1,11,[15][16][17][18] Foram feitas 12 combinações entre os níveis dos três fatores e cinco repetições referentes à combinação no ponto central para estimativa do erro residual, totalizando 17 ensaios experimentais para cada material de eletrodo (alumínio e ferro); tendo como variável resposta a remoção percentual de DQO total, (Tabela 1). O programa MINITAB® 16 (Minitab Inc., USA) 28 foi utilizado na construção dos modelos estatísticos.…”
Section: Planejamento Experimentalunclassified
“…Ao final, os eletrodos foram lavados para remover possíveis lipídeos aderidos à superfície e levados à estufa a 105 ± 2 °C e seu peso foi determinado. 18 Os resultados do desgaste real obtido pela diferença de pesos dos eletrodos foi comparado com o resultado expressos pela lei de Faraday. A lei de Faraday descrita pela Equação 3 pode ser usada para relacionar a massa do metal gerada pelo sistema eletrolítico com a intensidade de corrente (I) e o tempo de eletrólise (t).…”
Section: Cálculo Do Desgaste De Eletrodosunclassified
See 2 more Smart Citations