2021
DOI: 10.1109/tpwrd.2020.3032220
|View full text |Cite
|
Sign up to set email alerts
|

Technical Constrained Power Flow Studies for IDC-PFC Integrated Into the MT-HVDC Grids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 20 publications
0
3
0
Order By: Relevance
“…Based on the above analysis, the implementation of the system function modules is written according to the process in the following figure, as shown in Figures 7 and 8. In order to overcome the impact of dynamic changes in the network on network transmission, network QoS monitoring technology is introduced, and real-time monitoring lays a good foundation for intelligent transmission control [19,20]. Add a timestamp at the protocol layer to monitor the network delay, add two fields to each message, and record the last received timestamp (LRT) and the current sent timestamp (CST).…”
Section: System Function Realization Music Distance Educationmentioning
confidence: 99%
“…Based on the above analysis, the implementation of the system function modules is written according to the process in the following figure, as shown in Figures 7 and 8. In order to overcome the impact of dynamic changes in the network on network transmission, network QoS monitoring technology is introduced, and real-time monitoring lays a good foundation for intelligent transmission control [19,20]. Add a timestamp at the protocol layer to monitor the network delay, add two fields to each message, and record the last received timestamp (LRT) and the current sent timestamp (CST).…”
Section: System Function Realization Music Distance Educationmentioning
confidence: 99%
“…Fig. 1 (a) shows the topology of the studied IDC-PFC [28], which is formed of a dual H-bridge and a DC capacitor. The DC capacitor can eighter have a positive or negative direct voltage, and its value ( E ) is dependent on the voltages of the involved buses and the control variable setting D (duty cycle of the switches).…”
Section: Interline DC Power Flow Controller (Idc-pfc)mentioning
confidence: 99%
“…The IDC-PFCs are considered to be small converters compared to the VSC stations and their rating power is far lower than VSCs. Consequently, these devices have fewer/negligible losses in comparison to VSCs' losses [28]. In Fig.…”
Section: Interline DC Power Flow Controller (Idc-pfc)mentioning
confidence: 99%