Technical Note: Combination of multiple EPID imager layers improves image quality and tracking performance of low contrast‐to‐noise objects

Abstract: Combination of four conventional EPID layers significantly improves the EPID image quality and tracking accuracy for a poorly visible object which is moving with a frequency and amplitude similar to respiratory motion.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…The anticipated benefit of IGRT is realized basing on online confirmation of the registration at the time of radiotherapy. Megavoltage (MV) electronic portal imaging device (EPID) has been still widely used as an online verification tool for the treatment field and dosimetry in radiation therapy, although the emergence of kilovoltage (kV) imager mounted on a linear accelerator [1][2][3][4][5][6][7] .…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The anticipated benefit of IGRT is realized basing on online confirmation of the registration at the time of radiotherapy. Megavoltage (MV) electronic portal imaging device (EPID) has been still widely used as an online verification tool for the treatment field and dosimetry in radiation therapy, although the emergence of kilovoltage (kV) imager mounted on a linear accelerator [1][2][3][4][5][6][7] .…”
mentioning
confidence: 99%
“…Some efforts have been committed to the improvement of EPID image quality through the amendments of detector design. Yip et al 2 attempted to improve the quality of EPID images with a combination of four conventional EPID layers, which made a significant enhancement of tracking accuracy of poorly visible objects. Masatsugu Hariu et al 14 improved the EPID image quality by reducing the Compton scattered photons estimated at each point through the Monte Carlo simulation.…”
mentioning
confidence: 99%
“…Toward approach (2), Yip et al. tried to enhance the quality of EPID images by a combination of four conventional EPID layers 13 . An example of approach (3), Hariu et al.…”
Section: Related Workmentioning
confidence: 99%
“…12 Toward approach (2), Yip et al tried to enhance the quality of EPID images by a combination of four conventional EPID layers. 13 An example of approach (3), Hariu et al reduced Compton scattered photons using Monte Carlo simulation to improve the EPID image quality. 14 Moreover, some studies focused on the development of high detective quantum efficiency (DQE) detector configurations, which may improve quality of EPID imaging.…”
Section: Related Workmentioning
confidence: 99%
“…Gantry‐mounted MV and kV imaging systems have been the primary equipment deployed to detect the tumor or implanted fiducials during delivery. Although significant progress has been made in tracking implanted fiducials, technical transfer from research laboratory to routine clinic has met resistance, often due to concerns of the morbidity associated with the implantation of fiducials . Directly localizing tumors without the implanted fiducials is more desirable and remains the ultimate goal .…”
Section: Introductionmentioning
confidence: 99%