Technical note: Does scan resolution or downsampling impact the analysis of trabecular bone architecture?

Andrea Lukova,
Christopher J. Dunmore,
Zewdi J. Tsegai
et al.

Abstract: The “gold standard” for the assessment of trabecular bone structure is high‐resolution micro‐CT. In this technical note, we test the influence of initial scan resolution and post hoc downsampling on the quantitative and qualitative analysis of trabecular bone in a Gorilla tibia. We analyzed trabecular morphology in the right distal tibia of one Gorilla gorilla individual to investigate the impact of variation in voxel size on measured trabecular variables. For each version of the micro‐CT volume, trabecular bo… Show more