Technical note: Facilitating the use of low-cost methane (CH<sub>4</sub>) sensors in flux chambers – calibration, data processing, and an open source make-it-yourself logger

Abstract: Abstract. A major bottleneck regarding the efforts to better quantify greenhouse gas fluxes, map sources and sinks, and understand flux regulation, is the shortage of low-cost and accurate-enough measurement methods. The studies of methane (CH4) – a long-lived greenhouse gas increasing rapidly but irregularly in the atmosphere for unclear reasons, and with poorly understood source-sink attribution – suffer from such method limitations. This study present new calibration and data processing approaches for use o… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
14
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 5 publications
2
14
0
Order By: Relevance
“…The Python code needs modifications for use with other data, and the CH 4 sensor data cannot represent results from other sensors as sensor-specific calibration is needed. The Arduino code for the CH 4 -CO 2 -RH-T logger described in the Supplement is available at http://urn.kb.se/resolve?urn=urn:nbn: se:liu:diva-162780 (Bastviken and Duc, 2020).…”
Section: Discussionmentioning
confidence: 99%
“…The Python code needs modifications for use with other data, and the CH 4 sensor data cannot represent results from other sensors as sensor-specific calibration is needed. The Arduino code for the CH 4 -CO 2 -RH-T logger described in the Supplement is available at http://urn.kb.se/resolve?urn=urn:nbn: se:liu:diva-162780 (Bastviken and Duc, 2020).…”
Section: Discussionmentioning
confidence: 99%
“…In case of missing temperature and RH for a given AFC (due to K33 ELG sensor malfunction), values of temperature and RH from the closest AFC and closest in time were used, assuming the same temperature and RH in both chambers. Afterward, each CH 4 sensor was calibrated separately by following a procedure described in detail in Bastviken et al (45) using background air concentrations under different humidity and well mixed atmospheric conditions (wind speed higher >2 m/s) as reference data. Finally, including volume and area of the chamber, CH 4 flux (μmol•m −2 •h −1 ) was calculated as a relative change in CH 4 levels in a chamber over time.…”
mentioning
confidence: 99%
“…Based on existing knowledge of the expected air temperature variations at the in situ sampling point at the GrIS (Christiansen and Jørgensen, 2018), the humidity calibration was only carried out at a single temperature in this study. However, variations in the ambient air temperature are also expected to have a linear scaling effect for the type MOS system tested in this study (Bastviken et al, 2020;van den Bossche et al, 2017).…”
Section: Data Processingmentioning
confidence: 97%
“…Future tests should aim to investigate if the differences between the results from the laboratory and field calibration can be minimized by using the same type of datalogger and identical power supply (FX rechargeable lithium ion battery pack) both in the laboratory and in the field. Results from this type of test could reveal if field calibration for each individual MOS system is needed, similar to the approach in Bastviken et al (2020), or if batch calibrations of several identical MOS systems can be performed in the laboratory without the need for timeconsuming field calibration.…”
Section: Field Calibration Of the Metal Oxide Sensormentioning
confidence: 99%
See 1 more Smart Citation